An original Thinka practice paper modelled on the structure and difficulty of the Jun 2025 OCR A Level Physics A - H556 paper. Not affiliated with or reproduced from OCR.
H556/01 甲部
Answer all 15 items. Select one of four options for each and record its letter in the answer box. The paper advises spending no more than 30 minutes on this section.
15 题目 · 15 分
题目 1 · multiple_choice
1 分
A resistor has a potential difference of \(6.0 \pm 0.1\) V across it and a current of \(0.50 \pm 0.01\) A through it. What is the resistance with its absolute uncertainty?
A (1 mark). B1 for A only. Common errors: B adds absolute uncertainties (0.11); C uses only the p.d. percentage (0.2); D adds percentages wrongly/ignores division.
题目 2 · multiple_choice
1 分
A straight wire of length 0.25 m carries a current of 3.0 A in a uniform magnetic field of flux density 0.040 T. The wire is at \(30^\circ\) to the direction of the field. What is the magnitude of the force on the wire?
A.0.026 N
B.0.015 N
C.0.030 N
D.0.0075 N
查看答案详解收起答案详解
解题
\(F = BIL\sin\theta = 0.040 \times 3.0 \times 0.25 \times \sin 30^\circ = 0.015\) N. Answer B.
评分标准
B (1 mark). A uses cos 30°; C omits the sine; D applies the sine factor twice.
题目 3 · multiple_choice
1 分
A 0.50 kg metal block is heated by a 40 W electric heater for 150 s. Its temperature rises by 12 K. Assume all of the energy supplied is transferred to the block. What is the specific heat capacity of the metal?
A.\(83\ \mathrm{J\,kg^{-1}\,K^{-1}}\)
B.\(250\ \mathrm{J\,kg^{-1}\,K^{-1}}\)
C.\(500\ \mathrm{J\,kg^{-1}\,K^{-1}}\)
D.\(1000\ \mathrm{J\,kg^{-1}\,K^{-1}}\)
查看答案详解收起答案详解
解题
Energy \(= Pt = 40 \times 150 = 6000\) J. \(c = E/(m\Delta\theta) = 6000/(0.50 \times 12) = 1000\ \mathrm{J\,kg^{-1}\,K^{-1}}\). Answer D.
评分标准
D (1 mark). C omits the mass (6000/12); B divides by 0.50 and 12 and a further 2; A divides 1000 by 12 again.
题目 4 · multiple_choice
1 分
A parallel beam of X-rays passes through a uniform absorber. The half-value thickness of the absorber is 8.0 mm. What percentage of the incident intensity is transmitted through a thickness of 24 mm?
A.25%
B.12.5%
C.33%
D.67%
查看答案详解收起答案详解
解题
24 mm is three half-value thicknesses, so \(I/I_0 = (1/2)^3 = 1/8 = 12.5\%\). Answer B.
评分标准
B (1 mark). A uses two half-value thicknesses; C and D come from treating the attenuation as linear.
题目 5 · multiple_choice
1 分
A radioactive sample has an initial activity of 800 Bq. The half-life of the source is 2.0 hours. What is the activity after 6.0 hours?
A.100 Bq
B.200 Bq
C.267 Bq
D.400 Bq
查看答案详解收起答案详解
解题
6.0 h is three half-lives: \(800 \to 400 \to 200 \to 100\) Bq. Answer A.
评分标准
A (1 mark). B is two half-lives; C assumes linear decay; D is one half-life.
题目 6 · multiple_choice
1 分
Two coherent microwave sources emit waves of wavelength 3.0 cm in phase. At a point P the path difference from the two sources is 4.5 cm. Which row correctly describes the superposition at P?
A.maximum; phase difference \(3\pi\) rad
B.maximum; phase difference \(1.5\pi\) rad
C.minimum; phase difference \(3\pi\) rad
D.minimum; phase difference \(1.5\pi\) rad
查看答案详解收起答案详解
解题
Path difference \(= 4.5/3.0 = 1.5\lambda\), an odd number of half-wavelengths, so destructive interference (minimum). Phase difference \(= 1.5 \times 2\pi = 3\pi\) rad. Answer C.
评分标准
C (1 mark). Distractors misidentify the interference type or use \(\pi\) per wavelength incorrectly.
题目 7 · multiple_choice
1 分
The gravitational potential at the surface of a planet of radius \(R\) is \(-6.0 \times 10^{7}\ \mathrm{J\,kg^{-1}}\). What is the minimum work needed to raise a 2.0 kg mass from the surface to a height \(R\) above the surface?
A.\(3.0 \times 10^{7}\) J
B.\(6.0 \times 10^{7}\) J
C.\(1.2 \times 10^{8}\) J
D.\(1.8 \times 10^{8}\) J
查看答案详解收起答案详解
解题
\(V = -GM/r\). At distance \(2R\), \(V = -3.0 \times 10^7\ \mathrm{J\,kg^{-1}}\). \(\Delta V = 3.0 \times 10^7\). Work \(= m\Delta V = 2.0 \times 3.0 \times 10^7 = 6.0 \times 10^7\) J. Answer B.
评分标准
B (1 mark). A omits the mass; C is the work to reach infinity; D uses a wrong potential ratio.
题目 8 · multiple_choice
1 分
A ball is thrown horizontally at \(15\ \mathrm{m\,s^{-1}}\) from a point 10 m above level ground. Air resistance is negligible. What is the speed of the ball just before it hits the ground?
C (1 mark). A gives only the vertical component; B only the horizontal; D adds the components arithmetically.
题目 9 · multiple_choice
1 分
A student measures the potential difference across a resistor as \(V = 6.0 \pm 0.2\) V and the current through it as \(I = 0.50 \pm 0.02\) A. What is the resistance of the resistor, with its absolute uncertainty?
A.\(12 \pm 0.2\ \Omega\)
B.\(12 \pm 0.6\ \Omega\)
C.\(12 \pm 0.9\ \Omega\)
D.\(12 \pm 1.2\ \Omega\)
查看答案详解收起答案详解
解题
\(R = V/I = 6.0/0.50 = 12\ \Omega\). Percentage uncertainties: \(0.2/6.0 = 3.3\%\) and \(0.02/0.50 = 4.0\%\). Add for a quotient: \(7.3\%\). Absolute uncertainty \(= 0.073 \times 12 \approx 0.9\ \Omega\). Answer C.
评分标准
C (1 mark). B1 for the correct option only. Guidance: A arises from using only the voltage fractional uncertainty incorrectly; B from using a single fractional uncertainty; D from adding absolute uncertainties incorrectly.
题目 10 · multiple_choice
1 分
A radioactive sample has an activity of 800 Bq and a half-life of 6.0 hours. Background radiation may be ignored. How long will it take for the activity to fall to 100 Bq?
A.12 hours
B.18 hours
C.24 hours
D.36 hours
查看答案详解收起答案详解
解题
\(800 \to 400 \to 200 \to 100\) requires three half-lives. \(t = 3 \times 6.0 = 18\) hours. Answer B.
评分标准
B (1 mark). B1 for the correct option only. Guidance: A is two half-lives; C is four half-lives; D is an incorrect count (six half-lives).
题目 11 · multiple_choice
1 分
A ball is thrown horizontally at \(12\ \text{m s}^{-1}\) from the top of a cliff \(20\ \text{m}\) above level ground. Air resistance is negligible. What is the horizontal distance travelled by the ball before it hits the ground?
A.12 m
B.24 m
C.36 m
D.48 m
查看答案详解收起答案详解
解题
Vertical motion: \(20 = \tfrac{1}{2} g t^2\), so \(t = \sqrt{2 \times 20 / 9.81} = 2.02\) s. Horizontal distance \(= 12 \times 2.02 \approx 24\) m. Answer B.
评分标准
B (1 mark). B1 for the correct option only. Guidance: the working is M1 for time of fall from vertical motion, A1 for distance, but only the letter is credited.
题目 12 · multiple_choice
1 分
The gravitational potential at the surface of a planet is \(-6.4 \times 10^{7}\ \text{J kg}^{-1}\). What is the minimum energy that must be supplied to move a \(50\ \text{kg}\) probe from the surface to infinity?
A.\(-3.2 \times 10^{9}\ \text{J}\)
B.\(1.3 \times 10^{6}\ \text{J}\)
C.\(6.4 \times 10^{7}\ \text{J}\)
D.\(3.2 \times 10^{9}\ \text{J}\)
查看答案详解收起答案详解
解题
Energy required \(= m \Delta V = 50 \times (0 - (-6.4 \times 10^{7})) = 3.2 \times 10^{9}\) J. Answer D.
评分标准
D (1 mark). B1 for the correct option only. Guidance: A has the wrong sign; B divides instead of multiplying; C omits the mass.
题目 13 · multiple_choice
1 分
In a double-slit experiment the slit separation is \(0.50\ \text{mm}\) and the screen is \(2.0\ \text{m}\) from the slits. The fringe spacing is measured as \(2.4\ \text{mm}\). What is the wavelength of the light?
A.\(6.0 \times 10^{-7}\ \text{m}\)
B.\(6.0 \times 10^{-4}\ \text{m}\)
C.\(9.6 \times 10^{-6}\ \text{m}\)
D.\(2.4 \times 10^{-7}\ \text{m}\)
查看答案详解收起答案详解
解题
\(\lambda = a x / D = (0.50 \times 10^{-3} \times 2.4 \times 10^{-3}) / 2.0 = 6.0 \times 10^{-7}\) m. Answer A.
评分标准
A (1 mark). B1 for the correct option only. Guidance: B arises from failing to convert millimetres to metres; C from inverting the relationship.
题目 14 · multiple_choice
1 分
A spectral line has wavelength \(500\ \text{nm}\) in the laboratory. In light from a distant galaxy the same line is observed at \(505\ \text{nm}\). What is the recession speed of the galaxy?
A.\(1.5 \times 10^{6}\ \text{m s}^{-1}\)
B.\(6.0 \times 10^{6}\ \text{m s}^{-1}\)
C.\(3.0 \times 10^{8}\ \text{m s}^{-1}\)
D.\(3.0 \times 10^{6}\ \text{m s}^{-1}\)
查看答案详解收起答案详解
解题
\(\Delta\lambda / \lambda = v / c\), so \(v = (5/500) \times 3.00 \times 10^{8} = 3.0 \times 10^{6}\ \text{m s}^{-1}\). Answer D.
评分标准
D (1 mark). B1 for the correct option only. Guidance: C omits the fractional shift; A and B are factor-of-two errors.
题目 15 · multiple_choice
1 分
A straight wire of length \(0.40\ \text{m}\) carries a current of \(5.0\ \text{A}\) in a uniform magnetic field of flux density \(0.20\ \text{T}\). The wire makes an angle of \(30^\circ\) with the field direction. What is the magnitude of the force on the wire?
A.0.10 N
B.0.35 N
C.0.20 N
D.0.40 N
查看答案详解收起答案详解
解题
\(F = B I L \sin\theta = 0.20 \times 5.0 \times 0.40 \times \sin 30^\circ = 0.20\) N. Answer C.
评分标准
C (1 mark). B1 for the correct option only. Guidance: B uses cosine instead of sine; D omits the angle; A is a factor-of-two error.
Answer every question and show working where appropriate. Questions use lettered parts and Roman-numeral subdivisions where needed. Two six-mark responses assess the quality of extended reasoning; these marks are included within the question totals.
8 题目 · 85 分
题目 1 · structured
6 分
A narrow parallel beam of X-rays passes through a sheet of aluminium of thickness \(2.0\ \text{mm}\). The intensity of the transmitted beam is \(35\%\) of the incident intensity. The intensity \(I\) of the beam after passing through a thickness \(x\) of a material is given by \(I = I_0 e^{-\mu x}\), where \(\mu\) is the linear attenuation coefficient.
(a) Calculate \(\mu\) for aluminium, in \(\text{mm}^{-1}\). [2]
(b) Determine the thickness of aluminium needed to reduce the intensity of the beam to \(10\%\) of its incident value. [2]
(c) The aluminium sheet is used as a filter in an X-ray machine for imaging a broken arm. Explain why the filter improves the quality of the image and reduces the dose to the patient. [2]
(c) Low-energy photons have a larger attenuation coefficient, so they are absorbed in the soft tissue of the patient. They add to the dose but are not transmitted to the detector, so they do not contribute to the image. The filter removes them from the beam, reducing the dose, and the remaining higher-energy beam gives a sharper image with better contrast between bone and tissue.
评分标准
(a) M1: rearranges to \(\mu = -\ln(0.35)/2.0\) (or equivalent use of ln). A1: \(\mu = 0.52\) or \(0.525\ \text{mm}^{-1}\). Allow 2 or more s.f. Allow \(525\ \text{m}^{-1}\) if converted correctly.
(b) M1: \(x = \ln(10)/\mu\) (or \(\ln(1/0.10)/\mu\)). A1: \(4.4\ \text{mm}\) (accept 4.38 to 4.40, AW). ECF from (a) for the A mark. Allow a correct alternative method using (a) and the ratio of ln values.
(c) B1: low-energy (soft) X-ray photons are absorbed more readily / strongly attenuated by the filter (or by the patient's tissue). B1: these photons would be absorbed in the patient, adding to the dose without reaching the detector / contributing to the image, so removing them reduces dose and improves contrast or sharpness. Allow: beam becomes more penetrating / more monochromatic. Ignore: statements that the filter reduces intensity only. NOT: the filter absorbs all photons equally.
题目 2 · structured
7 分
A narrow, parallel beam of X-rays is directed at a sheet of aluminium. The intensity of the incident beam is \(840\ \text{W m}^{-2}\). The intensity of the beam emerging from a sheet of thickness \(4.0\ \text{mm}\) is \(210\ \text{W m}^{-2}\).
(a) (i) Show that the linear attenuation coefficient \(\mu\) of aluminium for these X-rays is approximately \(350\ \text{m}^{-1}\). [2]
(ii) Calculate the thickness of aluminium needed to reduce the intensity of the incident beam to \(5.0\%\) of its initial value. [2]
(b) Determine the half-value thickness of aluminium for these X-rays. [1]
(c) A thin aluminium filter is placed in the beam close to the X-ray tube in a hospital radiography unit. Explain why the filter improves the safety of the procedure without greatly reducing the quality of the image. [2]
查看答案详解收起答案详解
解题
(a)(i) \(I = I_0 e^{-\mu x}\), so \(210 = 840\,e^{-\mu(0.0040)}\). Then \(e^{-\mu x}=0.25\), so \(\mu = \ln 4/0.0040 = 1.386/0.0040 = 347\ \text{m}^{-1}\), which is approximately \(350\ \text{m}^{-1}\). (a)(ii) \(I/I_0 = 0.050\), so \(\mu x = \ln 20 = 3.00\). \(x = 3.00/347 = 8.6\times10^{-3}\ \text{m}\) (8.6 mm). (b) \(x_{1/2} = \ln 2/\mu = 0.693/347 = 2.0\times10^{-3}\ \text{m}\) (2.0 mm). This is consistent with 4.0 mm being two half-value thicknesses (840 to 420 to 210). (c) Low-energy photons are strongly attenuated by the body (large \(\mu\)), so they are absorbed in the skin and tissue near the surface and add to the dose without reaching the detector. The aluminium filter removes a large fraction of these low-energy photons. Higher-energy photons are attenuated much less, so they pass through the filter and the patient to form the image, and image quality is little affected.
评分标准
(a)(i) M1: correct substitution into \(I = I_0 e^{-\mu x}\) with ratio 0.25 (or 4) and ln taken [1]. A1: \(\mu = 347\ \text{m}^{-1}\) shown, with an unrounded value (or 3 s.f.) seen before the final statement [1]. Allow 0.347 mm^-1 or 0.347 per mm only with consistent units. Allow the half-value method: two half-value thicknesses so \(x_{1/2} = 2.0\) mm, then \(\mu = \ln 2/x_{1/2}\) (M1), \(= 347\ \text{m}^{-1}\) (A1). (a)(ii) C1/M1: \(\ln(0.050)=-\mu x\) or \(\ln 20 = \mu x\) [1]. A1: \(x = 8.6\times10^{-3}\ \text{m}\) (8.6 mm) [1]. Allow 8.6 to 8.7 mm; ECF from a wrong \(\mu\) in (a)(i) only if \(\mu\) was calculated, not the given 350. Using \(\mu=350\) gives 8.56 mm: allow. NOT 5.0 as a fraction used in place of 0.050 (gives zero for the second mark). (b) B1: 2.0 mm (\(2.0\times10^{-3}\) m), from \(\ln 2/\mu\) or from 4.0 mm / 2. Allow 1.98 to 2.0 mm. ECF from \(\mu\) in (a)(i). [1] (c) B1: low-energy (soft) X-ray photons are absorbed by the filter / are preferentially attenuated (AW higher attenuation coefficient) [1]. B1: these photons would be absorbed by the patient (skin) and so increase dose without contributing to the image; high-energy photons pass through to form the image [1]. Allow ora: the filter hardens the beam. Ignore reference to the wavelength of the X-rays unless connected to energy. NOT 'the filter blocks all radiation' or 'filter removes harmful radiation' without reference to energy.
题目 3 · 結構題
8 分
A narrow, parallel beam of X-rays of intensity \(I_0\) is directed at a sheet of aluminium. The intensity \(I\) of the beam transmitted through a thickness \(x\) of aluminium is given by
\(I = I_0 e^{-\mu x}\)
where \(\mu\) is the linear attenuation coefficient. For this beam, the value of \(\mu\) for aluminium is \(140\,\text{m}^{-1}\).
(a) Calculate the fraction \(\dfrac{I}{I_0}\) of the intensity transmitted through a sheet of aluminium of thickness \(4.0\,\text{mm}\).
\(\dfrac{I}{I_0} =\) ........................ [2]
(b)* A technician has an X-ray source, a detector that measures the intensity of the transmitted beam, and a set of identical thin sheets of an unknown metal. The technician wishes to determine \(\mu\) for the metal using this apparatus.
Describe a method that the technician could use and explain how the results should be analysed to obtain a value for \(\mu\). Your answer should include:
- the measurements to be made and how the procedure is carried out so that the results are reliable - how a suitable graph is plotted and how \(\mu\) is found from it - one safety precaution and one source of uncertainty in the experiment.
(b) Measure the background count/intensity with the source blocked and subtract it. Measure the thickness of a sheet with a micrometer, then record the transmitted intensity \(I\) for increasing numbers of sheets (thickness \(x\)), keeping the source-detector distance fixed and using a narrow collimated beam. Repeat each reading and average. Taking natural logs gives \(\ln I = \ln I_0 - \mu x\). Plot \(\ln I\) against \(x\): a straight line with negative gradient, so \(\mu = -\text{gradient}\). Safety: shield the source with lead, keep exposure time short, stay at a distance or behind a screen, and do not stand in the beam. Uncertainty: random variation in the detector reading, or the uncertainty in the sheet thickness, or sheets not exactly identical.
评分标准
(a) M1: \(\mu x = 140 \times 4.0\times10^{-3} = 0.56\) (unit conversion from mm to m must be correct). A1: \(I/I_0 = e^{-0.56} = 0.57\) (0.571). Allow 57% or answers to 2 s.f. or more. ECF from an incorrect \(\mu x\) for A1 only if the exponential is evaluated correctly. Answer of 0.57 with no working gets 2.
(b)* Level of response, assessed holistically (6 marks).
Band 3 (5-6 marks): A complete, logically structured method which includes measurements, repeated/controlled procedure, a correct linearised graph with the gradient linked to \(\mu\), and both a safety precaution and a source of uncertainty. The reasoning is clear and well supported by physics, with at most minor omissions.
Band 2 (3-4 marks): A method covering most strands, e.g. the measurement of I with varying thickness and a mostly correct graph, but one strand is missing or weak (e.g. no mention of safety or uncertainty, or no control of variables, or the graph relationship is not explained fully).
Band 1 (1-2 marks): Some relevant points made (e.g. measure I for different thicknesses, or plot a graph) but the method is incomplete, or the analysis is not linked to \(I = I_0e^{-\mu x}\). Little structure.
0 marks: No creditworthy response.
Indicative scientific points (not a compulsory script): - measure background and subtract (correct for background) - measure thickness of sheets with micrometer / vernier calipers; use stack of n sheets - measure transmitted intensity I for a range of thicknesses x, including x = 0 for I0 - fixed source-detector distance, same beam alignment / narrow collimated beam / same source settings - repeat readings and average - \(\ln I = \ln I_0 - \mu x\) - plot \(\ln I\) (or \(\ln(I/I_0)\)) on the y-axis against x on the x-axis - straight line with negative gradient; \(\mu = -\) gradient (large triangle) - safety: lead shielding, minimise exposure time, keep distance, do not stand in beam, warning signs/ trained operator - uncertainty: random fluctuation in readings, thickness measurement, non-identical sheets, detector resolution, beam not perfectly narrow
Allow lg instead of ln only if the gradient is correctly converted (\(\mu = -2.303\times\) gradient). NOT a graph of I against x with gradient equal to \(\mu\). Ignore reference to half-value thickness unless the method is otherwise correct.
题目 4 · 結構題 with short parts and extended response
9 分
A radiographer is imaging a patient's forearm using a narrow, parallel beam of X-rays. The intensity of X-rays transmitted through a thickness \(x\) of a uniform material is given by \(I = I_0 e^{-\mu x}\), where \(\mu\) is the linear attenuation coefficient.
For the X-ray photons used, a certain type of tissue has \(\mu = 0.28\ \text{cm}^{-1}\).
(a) (i) Calculate the fraction of the incident intensity that is transmitted through 6.0 cm of this tissue. [2]
(ii) Show that the half-value thickness of this tissue is approximately 2.5 cm. [1]
(b)* The radiographer places a thin aluminium sheet in the beam before it reaches the patient. The detector then records an image in which bone appears clearly distinguished from soft tissue.
Explain how the image is formed and how the quality of the image and the safety of the patient are affected by the aluminium sheet. Your answer should include: - why bone and soft tissue produce different intensities at the detector, - the name of one process by which X-ray photons are attenuated in the body, - the effect of the aluminium sheet on the beam and why this is beneficial. [6]
(a)(ii) At the half-value thickness \(I/I_0 = 0.5\), so \(\ln 2 = \mu x_{1/2}\). Then \(x_{1/2} = 0.693/0.28 = 2.48\ \text{cm} \approx 2.5\ \text{cm}\).
(b) Bone has a larger attenuation coefficient than soft tissue (higher density and proton number), so it attenuates the beam more strongly by the photoelectric effect (also Compton scattering). The transmitted intensity behind bone is therefore lower than behind soft tissue, giving contrast between the two regions of the image. The aluminium sheet absorbs low-energy (soft) X-ray photons, which are strongly attenuated and would be absorbed in the patient's tissue without reaching the detector. Removing them reduces the dose to the patient while leaving the higher-energy photons that form the image. The beam becomes more penetrating (harder) and more nearly of one energy, which gives a more consistent image, although the overall intensity at the detector is reduced slightly.
评分标准
(a)(i) M1: substitution \(e^{-0.28\times6.0}\) or \(e^{-1.68}\) [1]. A1: 0.19 (allow 0.186; 19% accept) [1]. Guidance: answer of 5.4 to 5.5 (inverse) scores M1 only; do not penalise 2 s.f. or 3 s.f.
(a)(ii) B1: \(0.5 = e^{-\mu x}\) so \(x = \ln 2/\mu\), and evaluates \(0.693/0.28 = 2.48\) (cm) [1]. Guidance: the working must show the calculated value to at least 2 s.f. before rounding to 2.5.
(b)* Level of response, 6 marks. Indicative scientific points: - Bone has a greater attenuation coefficient / is denser / has a higher proton number than soft tissue (AW). - Bone absorbs or scatters more X-ray photons so the transmitted intensity is lower behind bone (ORA); regions of different intensity give contrast (bone appears lighter on the radiograph/lower exposure on detector, AW). - Named attenuation process: photoelectric effect, Compton scattering, (coherent/simple scattering or pair production, the latter only at much higher photon energies). Allow any one correctly named process. - The aluminium sheet (filter) preferentially removes low-energy photons (since attenuation is greater for lower photon energy). - Low-energy photons would be absorbed by the patient's tissue and not contribute to the image, so the filter reduces patient dose. - The remaining beam has a higher mean photon energy / is harder / more penetrating; image quality is maintained or improved (a small reduction in total intensity may be mentioned).
5-6 marks: Relevant, well-supported reasoning covering all three bullet strands. Links the differing attenuation of bone and tissue to intensity differences and contrast, names a process correctly, and explains the filtering of low-energy photons with its effect on dose. The answer is logically structured and complete. 3-4 marks: Addresses at least two strands with some correct reasoning, but one is incomplete, or links between ideas are limited (e.g. states that the filter reduces dose without saying why, or states bone absorbs more without relating to intensity or contrast). 1-2 marks: Isolated correct statements from the indicative content, with little or no development or linking. 0 marks: No creditworthy response. Guidance: Ignore reference to the film being darker/lighter provided contrast is explained consistently. NOT 'bone blocks all X-rays'. NOT 'filter removes all low-energy photons' without qualification (AW partial). Do not credit ionisation of the aluminium as the reason for the filter.
题目 5 · 結構題 with short parts and extended response
10 分
A narrow parallel beam of monochromatic X-rays is directed at a uniform sheet of aluminium of thickness \(x\). The transmitted intensity \(I\) is related to the incident intensity \(I_0\) by
\(I = I_0 e^{-\mu x}\)
where \(\mu\) is the linear attenuation coefficient. For this beam in aluminium, \(\mu = 0.80\,\text{cm}^{-1}\).
(a) Show that the thickness \(x_{1/2}\) of aluminium that reduces the intensity to one half of \(I_0\) is given by \(x_{1/2} = \dfrac{\ln 2}{\mu}\). [2]
(b) Calculate the thickness of aluminium needed to reduce the transmitted intensity to 5.0% of \(I_0\). [2]
(c)* A radiographer images a limb using X-rays. The beam passes through 4.0 cm of tissue. In one path the tissue is entirely soft tissue, with \(\mu = 0.18\,\text{cm}^{-1}\). In a second path, 1.0 cm of the soft tissue is replaced by bone, with \(\mu = 0.62\,\text{cm}^{-1}\).
Discuss how the quality of the image of the bone is affected by:
- the contrast between the two paths, using the data above to support your answer - the use of a contrast medium when the organ of interest is soft tissue - the sharpness of the image.
In your answer, you should include a calculation of the ratio of the intensity emerging from the second path to the intensity emerging from the first path. [6]
查看答案详解收起答案详解
解题
(a) Set \(I = I_0/2\): \(\tfrac{1}{2} = e^{-\mu x_{1/2}}\). Taking natural logarithms: \(\ln(1/2) = -\mu x_{1/2}\), so \(-\ln 2 = -\mu x_{1/2}\) and \(x_{1/2} = \ln 2/\mu\).
(c) Path 1: \(I_1 = I_0 e^{-0.18\times 4.0} = I_0 e^{-0.72}\). Path 2: 3.0 cm soft tissue and 1.0 cm bone: \(I_2 = I_0 e^{-(0.18\times 3.0 + 0.62\times 1.0)} = I_0 e^{-1.16}\). Ratio \(I_2/I_1 = e^{-0.44} = 0.64\). So the intensity through bone is only about 36% lower than through soft tissue alone, so contrast is modest: bone is distinguishable but not strongly. Contrast is the difference in degree of blackening between adjacent regions and depends on the difference in attenuation coefficients. Soft tissues have very similar \(\mu\), so little contrast; a contrast medium of high atomic number (e.g. barium) has a much larger \(\mu\) and so strongly attenuates X-rays, making the organ stand out. Sharpness (clarity of edges) is improved by a small X-ray source/narrow, parallel beam, patient close to the detector (less geometric blurring/penumbra), a thin intensifying screen or small detector pixels, and a grid reducing scattered X-rays; filtering/low-energy removal and a short exposure also reduce unwanted dose and movement blur.
评分标准
(a) B1: \(\tfrac{1}{2} I_0 = I_0 e^{-\mu x_{1/2}}\) (or \(I/I_0 = 1/2\) substituted). B1: takes natural logs, \(\ln(1/2) = -\ln 2\), to reach \(x_{1/2} = \ln 2/\mu\). Guidance: the second mark needs a visible log step; do not allow a bare statement of the final expression.
(b) M1: \(0.050 = e^{-0.80x}\) or \(x = \ln(20)/0.80\) (allow \(\ln 0.05 = -0.80x\)). A1: \(x = 3.7\,\text{cm}\) (allow 3.74; allow 3.8 only if 3.75 shown). Guidance: a final answer of 3.7 with no working scores 2. Allow 0.037 m. ECF not applicable.
(c)* Level of response, assessed holistically.
Indicative scientific points: - Correct calculation: \(I_2/I_1 = e^{-(0.62-0.18)\times 1.0} = e^{-0.44} = 0.64\) (allow 0.64–0.65; the inverse 1.55 is accepted if clearly labelled as path 1 / path 2). Allow ECF into the interpretation. - Interpretation: contrast is the difference in blackening/intensity between regions, dependent on the difference in \(\mu\); a ratio of 0.64 means moderate contrast, only about 36% less intensity through bone. - Soft tissues have very similar \(\mu\), so adjacent soft organs give poor contrast. - A contrast medium (e.g. barium or iodine compound, high atomic number) has a much larger \(\mu\) (greater absorption, mainly by the photoelectric effect), so the organ is outlined clearly. - Sharpness: clear edges. Improved by small source or narrow beam, patient close to detector/film, thin or fine-grain intensifying screen or small pixel size, anti-scatter grid, short exposure to avoid movement blur. - Allow reference to scattering reducing contrast and sharpness.
5–6 marks: calculation present and correct (or only one slip), correctly interpreted for contrast, AND both the contrast-medium and sharpness strands covered with correct physics, linked and logically structured. Six marks requires at least two valid sharpness measures with reasons and a clear link between \(\mu\) values and the contrast. 3–4 marks: calculation attempted with correct method (may contain an arithmetic slip) and at least two of the three strands addressed with some correct physics, but reasoning is incomplete or one strand is only stated without explanation. 1–2 marks: isolated correct points (e.g. a contrast medium absorbs more; small source gives a sharper image; correct use of the attenuation equation for one path) without a coherent line of reasoning. 0 marks: no creditworthy response.
Ignore: references to dose or hazards unless linked to image quality. NOT: 'contrast medium makes X-rays pass through'. AW for sensible alternatives. Total 10 marks.
题目 6 · structured
13 分
A narrow parallel beam of monoenergetic X-rays is incident on a sheet of aluminium of thickness 6.0 mm. The intensity of the incident beam is \(620\ \mathrm{W\,m^{-2}}\). The intensity of the beam emerging from the sheet is \(217\ \mathrm{W\,m^{-2}}\).
The intensity \(I\) of the transmitted beam is related to the incident intensity \(I_0\) by \(I = I_0 e^{-\mu x}\), where \(x\) is the thickness of the absorber and \(\mu\) is the linear attenuation coefficient.
(a) Show that \(\mu\) for aluminium for these X-rays is approximately \(0.175\ \mathrm{mm^{-1}}\). [2]
(b) Calculate the thickness of aluminium needed to reduce the intensity of the incident beam to 5.0% of its original value. [2]
(c) Determine the half-value thickness of aluminium for these X-rays. [2]
(d) State the S.I. base unit of \(\mu\). [1]
(e)* A radiographer produces an X-ray image of a patient's broken forearm. A different patient swallows a barium meal before an X-ray image of the stomach is taken.
Describe and explain: - how the image of the broken forearm is formed, including why bone and soft tissue appear differently - how the sharpness of the image can be improved - why the barium meal is used.
You may assume the patient is exposed for the shortest time necessary. [6]
(c) At the half-value thickness \(I = I_0/2\), so \(x_{1/2} = \ln 2/\mu = 0.693/0.175 = 3.96\ \mathrm{mm}\).
(d) \(\mu = \ln(I_0/I)/x\), so the unit is \(\mathrm{m^{-1}}\).
(e) X-rays from a small source pass through the arm and are attenuated exponentially. Bone has a higher density and a higher proton number than soft tissue, so it has a larger \(\mu\) and absorbs more X-rays. Fewer X-rays reach the detector behind bone, so bone appears lighter on the film (shadow of the transmitted intensity), with the fracture seen as a gap or line. Sharpness is improved by using a small point source, a narrow collimated beam, placing the detector close to the patient, and a lead grid to absorb scattered X-rays. Barium has a high proton number, so it has a large attenuation coefficient. The soft stomach tissue has attenuation similar to its surroundings, so barium increases the contrast and makes the outline of the stomach visible. Barium sulfate is insoluble and so is not absorbed into the body.
评分标准
(a) M1: \(\ln(217/620)\) or \(\ln(0.35) = -\mu \times 6.0\) (or \(e^{-6\mu}=0.35\)). A1: \(\mu = 0.175\ \mathrm{mm^{-1}}\) with at least 3 s.f. shown (e.g. 0.1750 or 0.17497). Allow ECF only for correctly rearranged working. [2]
(b) M1: \(\ln(1/0.05)=\ln 20\) (= 2.996) divided by \(\mu\), or \(0.05 = e^{-0.175x}\). A1: 17 mm (17.1 mm). Allow 17.0 to 17.2. Allow answer in m (0.017 m). [2]
(c) M1: \(x_{1/2} = \ln 2/\mu\) (or \(0.5 = e^{-\mu x}\)). A1: 3.96 mm. Allow 4.0 mm. Allow ECF from (a) if a different \(\mu\) was used. [2]
(d) B1: \(\mathrm{m^{-1}}\). Allow 1/m. NOT \(\mathrm{mm^{-1}}\) or \(\mathrm{cm^{-1}}\). [1]
(e)* Level of response (6 marks). Assess holistically. Band 3 (5-6 marks): all three strands (image formation including bone vs soft tissue; sharpness; barium meal) are covered with correct, clearly linked physics. Explanations include the reasons (attenuation depends on density and proton number; contrast arises from different attenuation). The line of reasoning is coherent and well structured. Band 2 (3-4 marks): two strands are covered well, or all three covered with limited explanation or one significant omission/error. Reasoning is mostly logical. Band 1 (1-2 marks): some relevant points stated, with little or no explanation, or only one strand addressed. Band 0 (0 marks): no creditworthy response.
Indicative scientific points: - X-rays are produced by a small source and pass through the body; the detector (film/digital sensor) records transmitted intensity. - Different tissues attenuate X-rays differently; \(I = I_0 e^{-\mu x}\). - Bone has larger density / higher proton number (Z), so larger \(\mu\); more absorbed, so fewer X-rays reach the detector (appears lighter/whiter on a conventional film; a fracture shows as a darker line or gap). - Soft tissue absorbs less, so more X-rays are transmitted. - Sharpness: small (point) source / small focal spot; collimator for a narrow parallel beam; detector close to the patient to reduce geometric blurring/penumbra; patient still; anti-scatter (lead) grid; intensifying screen allows lower dose. - Barium meal: barium has a high proton number / high \(\mu\); stomach is soft tissue with similar attenuation to surroundings so there would be poor contrast; barium absorbs strongly, so the stomach's outline/lining is seen. Allow: barium is non-toxic as insoluble sulfate.
Allow: AW for all points. Accept 'contrast' for 'difference in shade'. Ignore: references to CT scans or ultrasound. NOT: bone 'reflects' X-rays; NOT: 'X-rays cannot pass through bone' (absorbed more, not blocked totally).
题目 7 · 結構題 with extended response
14 分
A technician investigates electromagnetic induction using a flat rectangular coil. The coil has \(N = 200\) turns and a cross-sectional area \(A = 4.0 \times 10^{-4}\ \mathrm{m^2}\). It is placed in a uniform magnetic field of flux density \(B = 0.35\ \mathrm{T}\).
(a) State Faraday's law of electromagnetic induction. [2]
(b) The plane of the coil is first perpendicular to the field. (i) Calculate the magnetic flux linkage of the coil. [1] (ii) The coil is turned through \(90^\circ\) in a time of \(0.040\ \mathrm{s}\), so that its plane becomes parallel to the field. Calculate the average e.m.f. induced in the coil during this movement. [2]
(c) The coil is now rotated at a constant frequency of \(25\ \mathrm{Hz}\) about an axis perpendicular to the field. The magnitude of the induced e.m.f. at any instant is \(\varepsilon = BAN\omega \sin \omega t\). Determine the maximum e.m.f. induced. [3]
(d)* The output of a generator is connected to a step-down transformer, which supplies a low-voltage lamp from a \(230\ \mathrm{V}\) alternating supply. Describe and explain: - how the transformer changes the p.d. using electromagnetic induction, - why the core is made from laminated soft iron, - why the efficiency of a real transformer is less than \(100\%\). [6]
查看答案详解收起答案详解
解题
(a) The magnitude of the induced e.m.f. is equal (directly proportional) to the rate of change of magnetic flux linkage; the sign is such that it opposes the change (Lenz's law).
(b)(i) \(N\Phi = BAN = 0.35 \times 4.0\times10^{-4} \times 200 = 0.028\ \mathrm{Wb\ turns}\). (b)(ii) Final flux linkage is zero, so change = \(0.028\). \(\varepsilon = 0.028 / 0.040 = 0.70\ \mathrm{V}\).
(c) \(\omega = 2\pi f = 2\pi \times 25 = 157\ \mathrm{rad\ s^{-1}}\). Maximum e.m.f. occurs when \(\sin\omega t = 1\): \(\varepsilon_{max} = BAN\omega = 0.028 \times 157 = 4.4\ \mathrm{V}\).
(d) An alternating current in the primary coil produces an alternating magnetic flux in the soft-iron core. This flux links the secondary coil, so a changing flux linkage induces an alternating e.m.f. in the secondary. Since \(V_s/V_p = N_s/N_p\), fewer turns on the secondary than on the primary gives a lower secondary p.d. The core is soft iron because it is easily magnetised and demagnetised, so little energy is lost in repeatedly reversing its magnetisation (hysteresis) and it concentrates the flux so that nearly all of it links the secondary. Lamination (thin insulated sheets) increases the resistance of paths for eddy currents, which reduces the currents induced in the core and so reduces heating. Real transformers are less than 100% efficient because of resistive heating (\(I^2R\)) in the windings, eddy currents and hysteresis in the core, and flux leakage so that not all primary flux links the secondary.
评分标准
(a) B1: e.m.f. (induced) is proportional / equal to rate of change. B1: of (magnetic) flux linkage. Allow 'rate of cutting of flux' for B1 only if 'linkage' not stated. Allow Lenz's law statement about opposing the change as an alternative B1 only if the first B1 is also awarded. NOT 'change of flux' without 'rate'.
(b)(i) B1: 0.028 (Wb turns) (accept 2.8 x 10^-2). Allow 0.028 with unit Wb or Wb turns; NOT missing unit if wrong unit given. (b)(ii) M1: \(\varepsilon = \Delta(N\Phi)/\Delta t\) with \(\Delta (N\Phi)=0.028\) and \(\Delta t = 0.040\). A1: 0.70 V. ECF from (b)(i). Allow 0.7 V. Ignore sign.
(c) B1: \(\omega = 2\pi \times 25 = 157\ \mathrm{rad\ s^{-1}}\) (or 160 to 2 s.f.). M1: \(\varepsilon_{max} = BAN\omega\) (sin = 1). A1: 4.4 V (accept 4.40, 4.5 from 160). ECF from (b)(i) value for BAN. NOT use of f in place of omega (gives 0.70 V: max 1 mark).
(d)* Level 3 (5-6 marks): all three bullet points are addressed with clear, correct, linked reasoning, including the role of changing flux in the core linking the secondary and the turns ratio, plus at least two valid energy-loss mechanisms explained. Level 2 (3-4 marks): two bullet points addressed with some correct reasoning, or all three addressed with limited explanation or minor errors. Level 1 (1-2 marks): some relevant correct points but reasoning is limited or incomplete. 0 marks: no creditworthy response. Indicative scientific points: alternating current in primary produces changing magnetic flux in the core; core links flux to secondary; changing flux linkage induces e.m.f. in the secondary (Faraday); \(V_s/V_p = N_s/N_p\) so fewer secondary turns gives lower p.d.; soft iron is easily magnetised and demagnetised / low hysteresis loss; soft iron has high permeability so flux is concentrated in the core; lamination increases resistance to eddy currents; reduces eddy current heating; real losses: resistance of windings (I^2R heating); eddy currents; hysteresis; flux leakage / not all flux links the secondary. Allow 'energy lost as heat/sound' for losses if linked to a cause. Ignore references to the transformer producing direct current. NOT 'transformer creates energy'.
题目 8 · 結構題 with short parts and extended response
18 分
A student determines the specific heat capacity \(c\) of an aluminium block using an electric heater. The heater is placed in a hole drilled in the block, which is wrapped in a layer of insulation. A thermometer is placed in a second hole. The heater is connected to a d.c. supply and the temperature of the block is recorded every 60 s.
The measurements are shown below.
- mass of block \(m = 1.00 \pm 0.01\) kg - potential difference across heater \(V = 12.0 \pm 0.1\) V - current in heater \(I = 4.00 \pm 0.05\) A
| time \(t\) / s | 0 | 60 | 120 | 180 | 240 | 300 | |---|---|---|---|---|---|---| | temperature \(\theta\) / °C | 20.0 | 23.1 | 26.3 | 29.4 | 32.6 | 35.7 |
(a) (i) Calculate the electrical power \(P\) supplied to the heater. [1]
(ii) Calculate the percentage uncertainty in \(P\). [2]
(b) A straight line of best fit on a graph of \(\theta\) against \(t\) passes through the first and last points in the table. Determine the gradient of this line. [2]
(c) Use your answers to (a)(i) and (b) to calculate \(c\) for aluminium. Give your answer to three significant figures. [2]
(d) The percentage uncertainty in the gradient is 3%. Determine the absolute uncertainty in \(c\) and hence write the value of \(c\) with its uncertainty. [3]
(e) The accepted value of \(c\) for aluminium is 897 J kg\(^{-1}\) K\(^{-1}\). Evaluate whether the student's result agrees with this value. [2]
(f)* Some energy is transferred from the block to the surroundings during the experiment. Discuss how this affects the experiment. Your answer should: - state and explain the effect on the measured value of \(c\) - describe how the data or graph could show whether energy losses are significant - suggest two changes to the procedure or apparatus that would improve the reliability of the result. [6]
查看答案详解收起答案详解
解题
(a)(i) \(P = VI = 12.0 \times 4.00 = 48.0\) W. (ii) \(\%V = 0.1/12.0 = 0.83\%\); \(\%I = 0.05/4.00 = 1.25\%\). Sum = 2.1%. (b) Gradient \(= (35.7-20.0)/300 = 15.7/300 = 0.0523\) K s\(^{-1}\). (c) \(P = mc\,\Delta\theta/\Delta t\), so \(c = P/(m \times \text{gradient}) = 48.0/(1.00 \times 0.05233) = 917\) J kg\(^{-1}\) K\(^{-1}\). (d) Total percentage uncertainty = 1% (mass) + 2.08% (power) + 3% (gradient) = 6.1%. Absolute uncertainty = 0.061 × 917 = 56 J kg\(^{-1}\) K\(^{-1}\). So \(c = (920 \pm 60)\) J kg\(^{-1}\) K\(^{-1}\). (e) The range is 861 to 973 J kg\(^{-1}\) K\(^{-1}\). 897 lies inside it, so the result is consistent with the accepted value. The measured value is slightly high, which is consistent with a small energy loss, but the uncertainty is too large to confirm a systematic error. (f) Energy lost means the block's temperature rises less than it would without losses, so the gradient is smaller and the calculated \(c\) is too large (the heater energy is assumed to all heat the block). Losses increase as the block gets hotter, so the graph curves and the gradient falls with time; a straight line suggests losses are small. Improvements: more or thicker insulation, a lid; add oil or conducting paste in the thermometer and heater holes for good thermal contact; start the block a few degrees below room temperature so the average temperature is close to room temperature; use a smaller temperature range or repeat the experiment and average.
评分标准
(a)(i) 48.0 W [B1]. Allow 48 W. (a)(ii) Percentage uncertainties in V and I found: 0.83% and 1.25% [M1]; added to give 2.1% [A1]. Allow 2.08% or 2%. Allow 1 mark for an absolute uncertainty of 1.0 W only if the percentage is not given. (b) Change in temperature 15.7 and time 300 s used [M1]; 0.0523 K s^-1 [A1]. Allow 0.052. Allow °C s^-1. (c) Use of c = P/(m × gradient) [M1]; 917 J kg^-1 K^-1 [A1]. Allow 918 if 0.0523 is used. ECF from (a)(i) and (b). Answer must be to 3 s.f. NOT 920. (d) Percentages added: 1 + 2.1 + 3 [M1]; 6.1% [A1]; absolute uncertainty about 56 (accept 55 to 57, or 60 to 1 s.f.) and c = 920 ± 60 or 917 ± 56 [A1]. ECF from (a)(ii) and (c). (e) Range of values 861 to 973 (or 897 compared with 917 ± 56) [B1]; states agrees / consistent as 897 lies within the range [B1]. ECF from (d). Allow a comment that a systematic error such as energy loss cannot be ruled out. (f)* Level 3 (5 to 6 marks): the effect of energy loss on c is stated and explained correctly, a valid way of detecting losses from the data or graph is described, and two appropriate improvements are given. The reasoning is logical and connects the strands, and the explanation is supported by physics. Level 2 (3 to 4 marks): two of the three strands are addressed with some supporting reasoning, or all three are addressed with limited explanation or one error. Level 1 (1 to 2 marks): one strand or isolated relevant statements, little or no explanation. Level 0 (0 marks): no creditworthy response. Indicative points: energy is lost to the surroundings so less energy heats the block; the temperature rise is smaller; the gradient is smaller; the calculated c is too large (ORA); losses increase as the temperature difference to the surroundings increases; the graph would curve (gradient decreases) rather than be straight; compare the gradient at the start and end of the heating; compare the energy supplied VIt with mcΔθ; more or better insulation; a lid on the block; thermal paste or oil in the holes; start below room temperature so the final temperature is above it by a similar amount; repeat and average; use a data logger or more precise thermometer. Ignore: 'human error', 'use a more accurate meter' without detail.
H556/02 甲部
Answer all 15 items. Select one of four options for each and record its letter in the answer box. The paper advises spending no more than 30 minutes on this section.
15 题目 · 15 分
题目 1 · multiple_choice
1 分
A student determines the resistance \(R\) of a resistor using \(R = V/I\). The potential difference is \(V = 6.0 \pm 0.2\,\text{V}\) and the current is \(I = 0.50 \pm 0.01\,\text{A}\).
What is the value of \(R\) with its absolute uncertainty?
A.\(12 \pm 0.4\,\Omega\)
B.\(12 \pm 0.6\,\Omega\)
C.\(12 \pm 1.2\,\Omega\)
D.\(12 \pm 0.2\,\Omega\)
查看答案详解收起答案详解
解题
\(R = 6.0/0.50 = 12\,\Omega\). Percentage uncertainty in \(V\) = \(0.2/6.0 \times 100 = 3.3\%\); in \(I\) = \(0.01/0.50 \times 100 = 2.0\%\). For a quotient the percentage uncertainties add: \(5.3\%\). Absolute uncertainty = \(0.053 \times 12 = 0.64 \approx 0.6\,\Omega\). Answer B.
评分标准
B1: B selected. Method (for reference): M1 add percentage uncertainties (3.3% + 2.0%); A1 convert to absolute uncertainty 0.6 Ω. A (0.4) uses only the uncertainty in V; C doubles the result; D is the uncertainty in V as an absolute value. Only the letter B is credited.
题目 2 · multiple_choice
1 分
A straight wire of length \(0.20\,\text{m}\) carries a current of \(3.0\,\text{A}\) in a uniform magnetic field of flux density \(0.40\,\text{T}\). The wire makes an angle of \(30^\circ\) with the direction of the field.
B1: C selected. Method: M1 use of \(F = BIL\sin\theta\) with the angle between wire and field; A1 0.12 N. A omits the angle; B uses cos 30°; D includes an extra factor of 0.5 (sin applied twice). Only the letter C is credited.
题目 3 · multiple_choice
1 分
An electric heater of power \(800\,\text{W}\) is switched on for \(105\,\text{s}\) in a well-insulated container holding \(0.50\,\text{kg}\) of water. The specific heat capacity of water is \(4200\,\text{J kg}^{-1}\text{K}^{-1}\). Assume all of the electrical energy is transferred to the water.
What is the rise in temperature of the water?
A.\(5.0\,\text{K}\)
B.\(10\,\text{K}\)
C.\(20\,\text{K}\)
D.\(40\,\text{K}\)
查看答案详解收起答案详解
解题
Energy supplied \(= Pt = 800 \times 105 = 8.4 \times 10^4\,\text{J}\). \(E = mc\Delta\theta\) so \(\Delta\theta = 8.4\times10^4 / (0.50 \times 4200) = 40\,\text{K}\). Answer D.
评分标准
B1: D selected. Method: M1 \(E = Pt\) equated to \(mc\Delta\theta\); A1 40 K. Accept 40 °C for a temperature change. A, B and C arise from omitting or mishandling the mass or time.
题目 4 · multiple_choice
1 分
A narrow beam of X-rays of intensity \(I_0\) passes through a uniform sheet of tissue of thickness \(4.0\,\text{cm}\). The linear attenuation coefficient of the tissue is \(\mu = 0.35\,\text{cm}^{-1}\).
What is the value of \(I/I_0\), where \(I\) is the transmitted intensity?
A.\(0.25\)
B.\(0.040\)
C.\(0.70\)
D.\(0.86\)
查看答案详解收起答案详解
解题
\(I = I_0 e^{-\mu x}\), so \(I/I_0 = e^{-0.35 \times 4.0} = e^{-1.4} = 0.247 \approx 0.25\). Answer A.
评分标准
B1: A selected. Method: M1 use of \(I = I_0e^{-\mu x}\) with \(\mu x = 1.4\); A1 0.25. C is \(e^{-0.35}\) (thickness ignored); D is \(e^{-0.15}\)-type error; B is a reciprocal-style error.
题目 5 · multiple_choice
1 分
The activity of a pure radioactive sample falls from \(640\,\text{Bq}\) to \(80\,\text{Bq}\) in \(45\) minutes. The background count rate is negligible.
What is the half-life of the source?
A.\(5.6\) minutes
B.\(15\) minutes
C.\(22\) minutes
D.\(45\) minutes
查看答案详解收起答案详解
解题
\(640 \to 320 \to 160 \to 80\) is three half-lives. So \(3t_{1/2} = 45\) minutes and \(t_{1/2} = 15\) minutes. Answer B.
评分标准
B1: B selected. Method: M1 identify three half-lives (ratio 8); A1 15 minutes. A divides by 8; C treats the fall as a single halving; D ignores the decay.
题目 6 · multiple_choice
1 分
A spectral line of wavelength \(500\,\text{nm}\) in the laboratory is observed from a distant galaxy. The galaxy is receding at a speed of \(1.5 \times 10^{7}\,\text{m s}^{-1}\).
What is the increase in the observed wavelength of the line?
B1: C selected. Method: M1 use of \(\Delta\lambda/\lambda \approx v/c\); A1 25 nm. A and D are powers-of-ten slips in \(v/c\) or the factor of 2.
题目 7 · multiple_choice
1 分
Light of wavelength \(600\,\text{nm}\) is incident on a double slit of slit separation \(0.30\,\text{mm}\). Fringes are observed on a screen \(2.0\,\text{m}\) from the slits.
What is the fringe spacing on the screen?
A.\(0.25\,\text{mm}\)
B.\(1.0\,\text{mm}\)
C.\(2.0\,\text{mm}\)
D.\(4.0\,\text{mm}\)
查看答案详解收起答案详解
解题
\(x = \lambda D / a = (600\times10^{-9} \times 2.0) / (0.30\times10^{-3}) = 4.0\times10^{-3}\,\text{m} = 4.0\,\text{mm}\). Answer D.
评分标准
B1: D selected. Method: M1 use of \(\lambda = ax/D\) rearranged for \(x\) with correct unit conversions; A1 4.0 mm. A, B and C come from incorrect powers of ten or halving the result.
题目 8 · multiple_choice
1 分
The gravitational potential at the surface of a planet of radius \(R\) is \(-4.0 \times 10^{7}\,\text{J kg}^{-1}\). A probe of mass \(25\,\text{kg}\) is raised from the surface to a point at a distance \(2R\) from the centre of the planet.
What is the increase in gravitational potential energy of the probe?
A.\(5.0 \times 10^{8}\,\text{J}\)
B.\(2.5 \times 10^{8}\,\text{J}\)
C.\(1.0 \times 10^{9}\,\text{J}\)
D.\(2.0 \times 10^{9}\,\text{J}\)
查看答案详解收起答案详解
解题
\(V = -GM/r\), so at \(2R\) the potential is half as negative: \(-2.0\times10^{7}\,\text{J kg}^{-1}\). \(\Delta V = +2.0\times10^{7}\,\text{J kg}^{-1}\). \(\Delta E = m\Delta V = 25 \times 2.0\times10^{7} = 5.0\times10^{8}\,\text{J}\). Answer A.
评分标准
B1: A selected. Method: M1 potential at \(2R\) is half the surface value; M1 \(\Delta E = m\Delta V\); A1 \(5.0\times10^{8}\) J. B uses a quarter of V; C uses the full surface value; D doubles it.
题目 9 · multiple_choice
1 分
The diameter \(d\) of a wire is measured as \(0.80\,\text{mm} \pm 0.02\,\text{mm}\). The cross-sectional area of the wire is calculated using \(A = \frac{\pi d^2}{4}\).
What is the percentage uncertainty in \(A\)?
A.\(2.5\%\)
B.\(3.1\%\)
C.\(5.0\%\)
D.\(6.3\%\)
查看答案详解收起答案详解
解题
Percentage uncertainty in \(d\) = \(0.02/0.80 \times 100 = 2.5\%\). Since \(A \propto d^2\), the percentage uncertainty in \(A\) is doubled: \(2 \times 2.5\% = 5.0\%\). Answer C.
评分标准
C (1 mark). B1 for correct answer only. Common errors: A (power not applied), D (percentage squared, 2.5² = 6.25).
题目 10 · multiple_choice
1 分
A pendulum of length \(L = 0.500 \pm 0.005\,\text{m}\) has period \(T = 1.42 \pm 0.02\,\text{s}\). The acceleration of free fall is determined using \(g = \frac{4\pi^2 L}{T^2}\).
What is the percentage uncertainty in the value of \(g\)?
A.\(3.8\%\)
B.\(2.4\%\)
C.\(2.8\%\)
D.\(4.2\%\)
查看答案详解收起答案详解
解题
Percentage uncertainty in \(L\) = \(0.005/0.500 = 1.0\%\). Percentage uncertainty in \(T\) = \(0.02/1.42 = 1.4\%\). Because \(T\) is squared, its contribution is \(2 \times 1.4 = 2.8\%\). Total = \(1.0 + 2.8 = 3.8\%\).
评分标准
A (1 mark). B1 for correct answer only. B: power of T not applied (1.0 + 1.4). C: contribution of L omitted.
题目 11 · multiple_choice
1 分
A straight wire of length \(0.15\,\text{m}\) carries a current of \(3.0\,\text{A}\). It lies in a uniform magnetic field of flux density \(0.40\,\text{T}\), with the wire at \(30^\circ\) to the direction of the field.
B (1 mark). B1 for correct answer only. C: cos 30° used. D: sin θ omitted. A: factor of 2 error.
题目 12 · multiple_choice
1 分
A narrow beam of X-rays passes through a uniform layer of material of thickness \(12.0\,\text{mm}\). The transmitted intensity is \(25\%\) of the incident intensity.
What is the linear attenuation coefficient \(\mu\) of the material?
A.\(0.058\,\text{mm}^{-1}\)
B.\(0.083\,\text{mm}^{-1}\)
C.\(0.25\,\text{mm}^{-1}\)
D.\(0.12\,\text{mm}^{-1}\)
查看答案详解收起答案详解
解题
\(I = I_0 e^{-\mu x}\) so \(0.25 = e^{-12.0\mu}\). Then \(\mu = \ln 4 / 12.0 = 1.386/12.0 = 0.12\,\text{mm}^{-1}\).
评分标准
D (1 mark). B1 for correct answer only. A: ln 2 used (50% transmitted). B: 1/12 used.
题目 13 · multiple_choice
1 分
The activity of a pure radioactive sample is \(640\,\text{Bq}\). After \(30\) minutes the activity is \(20\,\text{Bq}\). Background radiation may be ignored.
C (1 mark). B1 for correct answer only. A: 4 half-lives assumed. B: 3 half-lives assumed. D: 7 half-lives assumed.
题目 14 · multiple_choice
1 分
In a double-slit experiment using monochromatic light, the slit separation is \(0.50\,\text{mm}\) and the screen is \(2.0\,\text{m}\) from the slits. The fringe spacing on the screen is \(2.4\,\text{mm}\).
D (1 mark). B1 for correct answer only. A: extra factor of 2 in denominator. B: factor of 2 in numerator.
题目 15 · multiple_choice
1 分
A stone is thrown horizontally at \(12\,\text{m s}^{-1}\) from the edge of a vertical cliff, \(20\,\text{m}\) above level ground. Air resistance is negligible.
What is the horizontal distance from the base of the cliff to the point where the stone lands?
A (1 mark). B1 for correct answer only. D: time taken as h/v-type misuse. C: time doubled.
H556/02 乙部
Answer every question and show working where appropriate. Questions use lettered parts and Roman-numeral subdivisions where needed. Two six-mark responses assess the quality of extended reasoning; these marks are included within the question totals.
8 题目 · 85 分
题目 1 · 結構題 with extended response
6 分
A student has a solid aluminium cylinder of mass about \( 1\,\text{kg} \). The cylinder has one hole drilled for an electric immersion heater and a second hole for a thermometer. The student also has a joule meter (or a low-voltage d.c. supply with an ammeter and a voltmeter), a stopwatch, a top-pan balance and some thermal insulation.
*Plan an experiment to determine the specific heat capacity \( c \) of aluminium using this apparatus. Your answer should include:
- the measurements that should be taken and how they are taken - how \( c \) is obtained from the data, including a suitable graph - one source of systematic error and how the procedure reduces its effect.
[6]
查看答案详解收起答案详解
解题
Place the heater and thermometer in their holes (a drop of oil in the thermometer hole improves thermal contact). Measure the mass \( m \) of the cylinder with the balance. Wrap the cylinder in insulation. Connect the heater to the supply with the ammeter in series and the voltmeter in parallel with the heater, and record the initial temperature. Switch on and start the stopwatch. Record the p.d. \( V \), current \( I \) and the temperature \( \theta \) at regular intervals (e.g. every 60 s) for about 10 minutes, keeping \( V \) and \( I \) constant. Allow time for the heat to spread through the block before reading the thermometer.
Energy supplied \( = VIt \) and \( VIt = mc\Delta\theta \), so \( \theta = \dfrac{VI}{mc}\,t + \theta_0 \). Plot \( \theta \) (y-axis) against \( t \) (x-axis). The gradient is \( \dfrac{VI}{mc} \), so \( c = \dfrac{VI}{m \times \text{gradient}} \).
Systematic error: thermal energy is lost to the surroundings, so the measured temperature rise is too small and \( c \) is overestimated. Insulation reduces the loss; also starting the block a few degrees below room temperature and ending the same amount above it makes gains and losses roughly cancel. Using the gradient of the graph also reduces the effect of the thermometer not being in equilibrium initially.
评分标准
Extended response, level of response, 6 marks. Indicative scientific points (not a compulsory script):
1. Mass of cylinder measured with the balance (B). 2. Heater and thermometer in holes, with good thermal contact (e.g. oil) and insulation around the cylinder (B). 3. Measure V and I (or joule meter reading) and the time with a stopwatch, with temperature recorded at regular intervals while the power is constant (B). 4. Use of \( VIt = mc\Delta\theta \) (energy supplied = thermal energy gained) (B). 5. Plot \( \theta \) against \( t \) with gradient \( = VI/(mc) \), so \( c = VI/(m \times \text{gradient}) \) (B). Allow plot of energy against \( \theta \) with gradient \( mc \). 6. Systematic error identified (energy loss to surroundings, or heat capacity of heater/thermometer, or thermal lag) and a valid reduction (insulation, starting below and finishing above room temperature, or allowing time for conduction through block before reading) (B).
Band 3 (5 to 6 marks): the procedure is complete, logical and sequenced, measurements and the method of analysis are both correct and linked by the correct equation, and a systematic error with its reduction is clearly given. Band 2 (3 to 4 marks): a mostly correct procedure with measurements and some analysis, but one strand is missing, unclear or not linked (e.g. no graph or no gradient link, or no systematic error). Band 1 (1 to 2 marks): a few relevant points such as measuring mass, p.d., current, time or temperature without a coherent method. 0 marks: no creditworthy response.
Allow: use of a joule meter for energy. Ignore: repeat readings and averaging unless linked to a systematic error. NOT: a reduction in 'random' error given as the systematic-error reduction. AW for all points.
题目 2 · structured
9 分
21 A student determines the resistivity \(\rho\) of a uniform metal wire. The measurements are shown in the table.
(a) Calculate the cross-sectional area \(A\) of the wire and the percentage uncertainty in \(A\). [2]
(b) Calculate the resistance \(R\) of the wire and the percentage uncertainty in \(R\). [2]
(c) Use the equation \(\rho = \dfrac{RA}{L}\) to determine \(\rho\), with its absolute uncertainty. Give your answer to an appropriate number of significant figures. [3]
(d) Identify the measurement that contributes most to the uncertainty in \(\rho\). Suggest one change to the procedure that would reduce this uncertainty. [2]
查看答案详解收起答案详解
解题
(a) \(A = \pi d^2/4 = \pi (0.320\times10^{-3})^2/4 = 8.04\times10^{-8}\ \text{m}^2\). Percentage uncertainty in \(d\) = \(0.010/0.320 = 3.1\%\). \(A \propto d^2\), so the percentage uncertainty in \(A\) is \(2\times3.125 = 6.25\% \approx 6.3\%\).
(b) \(R = V/I = 1.45/0.250 = 5.80\ \Omega\). Percentage uncertainty in \(V\) = 0.69%; in \(I\) = 2.0%. Total = 2.7%.
(c) \(\rho = (5.80\times8.04\times10^{-8})/0.850 = 5.49\times10^{-7}\ \Omega\,\text{m}\). Percentage uncertainty in \(L\) = 0.24%. Total = \(6.25+2.7+0.24 = 9.2\%\). Absolute uncertainty = \(0.092\times5.49\times10^{-7} = 0.5\times10^{-7}\). So \(\rho = (5.5\pm0.5)\times10^{-7}\ \Omega\,\text{m}\).
(d) The diameter contributes most (6.3% of the 9.2% total) because it is squared. Take readings at several positions along the wire and in perpendicular directions with a micrometer, and use the mean. This reduces the effect of non-uniformity and random error.
评分标准
(a) B1: \(A = 8.04\times10^{-8}\ \text{m}^2\) (allow 8.0 and \(0.0804\ \text{mm}^2\) if unit consistent). B1: 6.3% or 6.25% (doubling the percentage uncertainty in \(d\)). NOT 3.1% only.
(b) B1 (M1): \(R = 5.80\ \Omega\). A1: 2.7% (accept 2.69%; from 0.69% + 2.0%). Allow 3% (1 s.f.) only if working shown.
(c) M1: \(\rho = RA/L\) with correct substitution. A1: \(\rho = 5.5\times10^{-7}\ \Omega\,\text{m}\) (allow 5.49; ECF from (a) and (b)). A1: uncertainty \(\pm0.5\times10^{-7}\ \Omega\,\text{m}\) (from summed percentages, about 9.2%, ECF), with the uncertainty given to 1 s.f. and \(\rho\) to the same decimal place. Ignore uncertainty given to 2 s.f. if the value is consistent, but do not award the final A1 if the decimal places do not match.
(d) B1: the diameter (AW: \(d\) or area). Allow ECF from (a)-(c) if the percentage uncertainties support the choice. B1: a valid improvement, for example repeat readings of \(d\) at different points along the wire and in different orientations, and average; or use a thicker wire; or use a micrometer with finer resolution. NOT 'use more accurate apparatus' without detail. Ignore changes to \(L\), \(V\) or \(I\).
题目 3 · structured
10 分
A student determines the resistivity \(\rho\) of the metal of a uniform wire. The diameter of the wire is measured with a micrometer screw gauge as \(d = 0.38 \pm 0.01\) mm. The length of wire between two contacts is \(L = 0.800 \pm 0.002\) m. The student measures the potential difference \(V\) across this length for several currents \(I\) and plots a graph of \(V\) against \(I\). The gradient gives the resistance \(R = 5.2 \pm 0.2\ \Omega\).
(a) Calculate the percentage uncertainty in the cross-sectional area \(A\) of the wire. [1]
(b) Calculate the resistivity \(\rho\) of the metal. Give your answer in \(\Omega\) m to two significant figures. [2]
(c) Determine the absolute uncertainty in \(\rho\). [1]
(d)* Describe how the student should carry out the experiment to obtain reliable values of \(d\), \(L\) and \(R\), and explain why determining \(R\) from the gradient of a graph is better than using a single pair of readings of \(V\) and \(I\). [6]
查看答案详解收起答案详解
解题
(a) \(A = \pi d^2/4\), so percentage uncertainty in \(A\) is \(2\times(0.01/0.38)\times100 = 2\times2.63 = 5.3\%\).
(d) Measure d at several points along and around the wire with a micrometer, zero check first, and average. Measure L with a metre rule from contact to contact with the wire straight and taut. Vary current with a variable resistor, record V and I for several values, keep current small / switch off between readings to avoid heating (which changes resistance). Plot V against I, draw a line of best fit, and take the gradient. Graph averages random error, reveals anomalies and systematic offsets (zero error), whereas a single pair gives no check on reliability.
评分标准
(a) B1: 5.3% (allow 5%; accept 5.26).
(b) M1: \(A = \pi d^2/4\) evaluated (\(1.1\times10^{-7}\) m\(^2\)) and use of \(\rho = RA/L\). A1: \(7.4\times10^{-7}\ \Omega\) m. Allow 7.3 to 7.4 if A rounded. NOT 1 s.f. answer for the A1.
(c) B1: \(\pm0.7\times10^{-7}\ \Omega\) m (percentage uncertainties 3.8 + 5.3 + 0.25 = 9.4%). ECF from (a) and (b).
(d)* Level of response, 6 marks. Band 3 (5 to 6 marks): Practical method for at least two of d, L and R is clear and includes specific precautions; explanation of the advantage of the graph is complete and linked to reducing random error and identifying anomalies or systematic error. Reasoning is logical and coherent. Band 2 (3 to 4 marks): Some correct practical detail for d, L or R and a partial explanation of the graph advantage; some gaps in logic. Band 1 (1 to 2 marks): Isolated relevant statements with little linkage. 0 marks: no creditworthy response. Indicative points: repeat d readings at different positions and orientations and average; check micrometer zero / correct zero error; ratchet used; L measured between contact points with wire straight; ruler with suitable resolution; vary the current using a variable resistor / potential divider and record several (V, I) pairs; keep current low or switch off between readings to avoid heating; line of best fit through data; gradient averages out random errors; anomalous points are identified; straight line through origin confirms ohmic behaviour; a non-zero intercept reveals systematic error; uncertainty in gradient can be found from worst-fit lines. Ignore references to repeating readings without averaging.
题目 4 · structured
10 分
A narrow beam of monochromatic X-rays passes through a uniform sheet of aluminium. The intensity \(I\) of the transmitted beam is given by \(I = I_0 e^{-\mu x}\), where \(x\) is the thickness of the sheet. The half-value thickness of aluminium for these X-rays is 2.4 mm.
(a) Show that the linear attenuation coefficient \(\mu\) of aluminium for these X-rays is approximately \(0.29\ \mathrm{mm^{-1}}\). [2]
(b) Calculate the fraction of the incident intensity transmitted through a sheet of thickness 7.0 mm. [2]
(c)* An X-ray image is taken of a patient's forearm to check for a fracture of a bone. An aluminium filter is placed in the beam before it reaches the patient.
Describe how the image is formed and explain why bone and soft tissue appear with different contrast. Explain the purpose of the aluminium filter. [6]
查看答案详解收起答案详解
解题
(a) At the half-value thickness \(I = I_0/2\), so \(\tfrac12 = e^{-\mu x_{1/2}}\), giving \(\mu = \ln 2/x_{1/2} = 0.693/2.4 = 0.289 \approx 0.29\ \mathrm{mm^{-1}}\).
(c) X-rays from a source pass through the arm and are detected by a film/digital detector behind it. Bone has a larger attenuation coefficient (higher density and effective atomic number, so more photoelectric absorption) than soft tissue, so less intensity is transmitted through bone, leaving a lighter/less exposed region. The difference in transmitted intensity gives contrast, and a fracture shows as a break in the bone shadow. The aluminium filter absorbs low-energy X-ray photons, which are strongly absorbed by the body and contribute to dose but not to the image. This reduces patient dose and gives a harder beam with better image quality.
评分标准
(a) M1: \(\tfrac12 = e^{-\mu x}\) with \(x = 2.4\) mm, or \(\ln 2 = \mu x\). A1: \(\mu = 0.693/2.4 = 0.289\) (shown to at least 2 s.f. before rounding to 0.29). Allow use of any numerical check that reproduces 0.29.
(b) C1: \(\mu x = 0.289\times7.0\) (= 2.02), or alternatively 7.0/2.4 = 2.9 half-lives. A1: 0.13 or 13%. Allow 0.12 to 0.14 (ignore rounding of \(\mu\) to 0.29 which gives 0.131). NOT a value of intensity in W m\(^{-2}\).
(c)* Level of response, 6 marks. Band 3 (5 to 6 marks): Describes image formation with detector and shadow; explains contrast through different attenuation of bone and soft tissue with a reason; explains the filter removing low-energy photons and reducing dose. Reasoning is clear, linked and logically ordered. Band 2 (3 to 4 marks): Two of the three strands addressed with some correct physics, or all three with partial explanations. Band 1 (1 to 2 marks): Isolated correct statements, for example bone absorbs more X-rays. 0 marks: no creditworthy response. Indicative points: X-rays produced and directed at the arm; detector or film placed on the opposite side; image is a shadow of transmitted intensity; bone has larger \(\mu\) (greater density / higher proton number, more photoelectric absorption); bone transmits lower intensity so appears lighter on the image (AW depending on detector type); fracture appears as a gap or line in the bone image; intensity falls exponentially with thickness; low-energy photons are absorbed more readily by tissue; filter removes these, which would add to dose without contributing to the image; reduces patient dose; narrower range of photon energies improves contrast / image quality. Allow ORA for soft tissue. Ignore references to ionisation damage unless linked to dose.
题目 5 · structured
10 分
A student determines the specific heat capacity of an aluminium block of mass 1.20 kg. An electric heater of power 60 W is placed in a hole in the block, and a thermometer in a second hole. The initial temperature of the block is 20.0 \(^\circ\)C. After the heater has been on for 300 s, the temperature is 36.0 \(^\circ\)C.
(a) Calculate the energy supplied by the heater in 300 s. [1]
(b) Calculate the specific heat capacity of the aluminium. [2]
(c) The accepted value is lower than the student's value. Explain why the experiment produces a value that is too large. [2]
(d) Suggest one change to the apparatus that would improve the result. [1]
(e) The temperature of the block is later 300 K. A sample of helium gas, treated as an ideal gas, is in thermal equilibrium with the block.
(i) Calculate the mean kinetic energy of a helium atom. [2]
(ii) The mass of a helium atom is \(6.64\times10^{-27}\) kg. Calculate the root-mean-square speed of the atoms. [2]
查看答案详解收起答案详解
解题
(a) \(E = Pt = 60\times300 = 1.8\times10^4\) J.
(b) \(E = mc\Delta\theta\), so \(c = 18000/(1.20\times16.0) = 938\ \mathrm{J\,kg^{-1}\,K^{-1}}\), about 940.
(c) Some energy is transferred to the surroundings and to the heater and thermometer, so the energy actually gained by the block is less than 18 000 J. The temperature rise is therefore smaller than expected if all energy went to the block, so \(c = E/(m\Delta\theta)\) with \(E\) too large gives a value that is too large.
(d) Wrap the block in thermal insulation (lagging).
(e)(i) \(E_k = \tfrac32 kT = 1.5\times1.38\times10^{-23}\times300 = 6.21\times10^{-21}\) J.
(ii) \(\tfrac12 m\langle c^2\rangle = 6.21\times10^{-21}\), so \(\langle c^2\rangle = 1.87\times10^6\ \mathrm{m^2\,s^{-2}}\) and \(c_{rms} = 1.37\times10^3\ \mathrm{m\,s^{-1}}\).
评分标准
(a) B1: \(1.8\times10^4\) J (18 000 J). Unit required.
(b) C1: \(c = E/(m\Delta\theta)\) with \(\Delta\theta = 16.0\) K. A1: 938 (J kg\(^{-1}\) K\(^{-1}\)); allow 940 or 9.4 x 10^2. ECF from (a). Allow J kg\(^{-1}\) \(^\circ\)C\(^{-1}\).
(c) B1: energy is lost (transferred) to the surroundings / not all the energy supplied heats the block (AW). B1: the energy used in the calculation is larger than the energy that actually raised the temperature of the block, so the calculated \(c\) is too large (AW; ORA). NOT 'heat is lost' alone for the second mark.
(d) B1: insulate / lag the block (accept lid, or add oil in the holes for better thermal contact). Ignore 'repeat readings'.
(e)(i) C1: \(E = \tfrac32 kT\). A1: \(6.21\times10^{-21}\) J. Allow \(6.2\times10^{-21}\) J.
A technician investigates how a narrow, parallel beam of monochromatic X-rays is attenuated by aluminium sheets. A detector placed behind the sheets records the intensity \(I\) of the transmitted beam. The intensity with no aluminium present is \(I_0 = 640\) arbitrary units. The relationship for attenuation is \(I = I_0 e^{-\mu x}\), where \(x\) is the thickness of aluminium and \(\mu\) is the linear attenuation coefficient.
(a) (i) State the graph that should be plotted to give a straight line from the relationship \(I = I_0 e^{-\mu x}\). [1]
(ii) Complete the table by calculating \(\ln I\) for \(x = 6.0\) mm. [1]
(iii) Use the first and last rows of the table to determine \(\mu\), in \(\text{mm}^{-1}\). [2]
(b) Calculate the thickness of aluminium needed to reduce the transmitted intensity to 5.0% of \(I_0\). [2]
(c)* A radiographer produces an X-ray image of a patient's forearm, and the image shows the bones clearly but shows little detail of the soft tissues.
Explain how the image is formed and why the soft tissue shows little contrast. In your answer you should: - explain the origin of the contrast between bone and soft tissue, - describe one way of improving the contrast of an internal soft organ, - explain why a thin aluminium filter is placed in the beam before the patient. [6]
查看答案详解收起答案详解
解题
(a)(i) \(\ln I = \ln I_0 - \mu x\), so plot \(\ln I\) (y-axis) against \(x\) (x-axis); gradient \(= -\mu\).
(b) \(0.050 = e^{-\mu x}\), so \(x = \ln(20)/\mu = 2.996/0.249 = 12.0\) mm (12 mm using \(\mu = 0.25\)).
(c) X-rays pass through the arm and are attenuated according to \(I = I_0 e^{-\mu x}\). Bone has a much larger attenuation coefficient (higher density and higher proton number, so more photoelectric absorption) than soft tissue, so less intensity is transmitted through bone and the detector or film shows bone as a lighter region (shadow). Different soft tissues have very similar densities and attenuation coefficients, so the transmitted intensities are almost equal and contrast is poor. A contrast medium such as a barium meal (high atomic number, strongly absorbing) fills the organ, e.g. the digestive tract, making it show clearly. Low-energy X-rays are absorbed by the body without contributing to the image and increase the dose; an aluminium filter preferentially absorbs these, so the patient dose is reduced and the beam is more nearly monochromatic and penetrating.
评分标准
(a)(i) B1: \(\ln I\) on the y-axis against \(x\) on the x-axis. Allow \(\lg I\) against \(x\). NOT \(I\) against \(x\).
(a)(ii) B1: 4.963. Allow 4.96.
(a)(iii) M1: gradient \(= (4.466 - 6.461)/8.0\) (or any correct use of two points), with \(\mu = -\)gradient. A1: \(\mu = 0.25\ \text{mm}^{-1}\) (accept 0.249 and range 0.24 to 0.26). Allow ECF for a wrong-sign gradient with M1 only.
(b) C1: \(\ln(0.050) = -\mu x\) or \(x = \ln 20/\mu\). A1: 12 mm (accept 11.9 to 12.1). ECF from (a)(iii) for \(\mu\). NOT use of 0.95 in place of 0.050.
(c)* Level of response, 6 marks.
5 to 6 marks: A clear, logically structured explanation covering all three bullets, with correct supporting physics (attenuation coefficient or density/proton number differences; high-Z contrast medium; filter removing low-energy photons so that dose is reduced). The strands are linked, e.g. contrast arises from differing transmitted intensities. Few or no errors.
3 to 4 marks: Explanation covers at least two bullets with some correct physics, or all three with limited supporting detail or a minor error. Reasoning is mostly coherent.
1 to 2 marks: Isolated correct statements, e.g. bone absorbs more X-rays than tissue, or barium improves contrast, with little explanation or linking.
0 marks: No creditworthy response.
Indicative scientific points: X-rays are attenuated exponentially, \(I = I_0 e^{-\mu x}\); bone has a larger \(\mu\) (greater density and atomic number; photoelectric absorption increases with \(Z\)); less transmission through bone gives a lighter (unexposed) region on film or a lower detector signal; soft tissues have similar \(\mu\), so similar transmitted intensities and low contrast; contrast medium such as barium or iodine compounds, strongly absorbing, high \(Z\); the filter absorbs low-energy (soft) X-rays which would be absorbed by the patient and not reach the detector, so it reduces dose and hardens the beam. Allow: use of a collimator or anti-scatter grid as an extra creditworthy point for sharpness. Ignore: references to ionisation risk without link to dose. NOT: X-rays 'reflected' by bone.
题目 7 · 結構題 with short parts and extended response
13 分
A technician prepares a small sample of a short-lived radioisotope and places it a fixed distance from a Geiger-Müller (GM) tube connected to a counter. The background count rate, measured with the sample removed, is \(8\ \text{s}^{-1}\).
With the sample in place, the count rate is \(128\ \text{s}^{-1}\) at time \(t = 0\). After \(50\) minutes the count rate is \(38\ \text{s}^{-1}\).
(a) (i) Show that the half-life of the isotope is \(25\) minutes. [3]
(ii) Calculate the decay constant \(\lambda\) of the isotope in \(\text{s}^{-1}\). [2]
(iii) The activity of the sample at \(t = 0\) is equal to the corrected count rate. Calculate the number of undecayed nuclei in the sample at \(t = 0\). [2]
(b)* A second sample, of unknown composition, may emit alpha particles, beta particles, gamma rays, or a combination of these. A GM tube, a counter, a ruler and a set of absorbers (paper, aluminium sheets of several thicknesses and a thick lead block) are available.
Describe how the technician could use this apparatus to decide which radiations are emitted, and explain how the risk to the technician is kept as low as reasonably practicable while the investigation is carried out. [6]
查看答案详解收起答案详解
解题
(a)(i) Corrected count rate at \(t=0\): \(128-8 = 120\ \text{s}^{-1}\). At 50 min: \(38-8 = 30\ \text{s}^{-1}\). \(30/120 = 1/4 = (1/2)^2\), so 50 min is two half-lives, giving \(T_{1/2} = 50/2 = 25\) min.
(b) Indicative method: measure the background count rate with no source and subtract it from all readings. Place the GM tube close to the source and record the corrected count rate. Place paper between source and tube: a large fall indicates alpha. Replace with aluminium sheets (a few millimetres): a further fall indicates beta. Then place thick lead: any remaining drop indicates gamma, since gamma is only gradually attenuated; a count rate unchanged by lead means little or no gamma. Repeat readings over a fixed time and average to reduce random error. Alpha has a range of only a few centimetres in air, so a count rate that falls to background at a distance of about 5 cm or more suggests alpha only; the inverse-square variation of the count rate with distance can distinguish gamma. Safety: handle the source with tongs, never by hand; keep it at the maximum practical distance and in its shielded container when not in use; minimise the exposure time; point the source away from people; wear gloves and wash hands afterwards; do not eat or drink in the area; keep a record of the source and store it in a locked lead-lined box.
评分标准
(a)(i) B1: subtracts background from both readings (120 and 30 s^-1). M1: identifies the ratio 30/120 = 1/4 as two half-lives (or equivalent halving method: 120 -> 60 -> 30). A1: T1/2 = 25 min (shown clearly, 50/2). Allow ECF only if background is subtracted. NOT 128 and 38 used directly (gives a different value).
(ii) C1/M1: converts 25 min to 1500 s AND uses \(\lambda = \ln 2 / T_{1/2}\). A1: \(4.6\times10^{-4}\ \text{s}^{-1}\) (accept \(4.62\times10^{-4}\)). Allow 0.028 min^-1 for M1 only if unit conversion missing (A0).
(iii) M1: \(N = A/\lambda\) with A = 120 s^-1. A1: \(2.6\times10^{5}\) (accept 2.59-2.60 x 10^5). ECF from (ii). NOT use of 128 s^-1 (gives 2.8 x 10^5, M1 only).
(b)* Level of response, six marks, assessed holistically.
Level 3 (5-6 marks): A logical, complete method is described covering background correction, a sequence of absorbers (paper, aluminium, lead) with what the changes in count rate show for each radiation type, AND at least two distinct, correctly explained safety measures (e.g. tongs, distance, time, shielded storage). Reasoning is clear and connects the observations to the conclusions about the radiation types.
Level 2 (3-4 marks): Method describes use of at least two types of absorber with a mostly correct interpretation, or gives a good method with limited safety, or good safety with a partial method. Some links between observation and conclusion are missing or lack clarity.
Level 1 (1-2 marks): Isolated relevant points, e.g. measures count rate with and without an absorber, or states one safety precaution, with little or no connection between them.
Level 0 (0 marks): No creditworthy response.
Indicative scientific points (not a compulsory script): measure and subtract background; record count rate with no absorber at fixed distance and time; paper stops alpha (large drop); a few mm of aluminium stops beta; thick lead needed to reduce gamma substantially; remaining count rate after lead close to background means no gamma; repeat and average readings; alpha range a few cm in air; use tongs, do not hold or point the source at anyone; store in a shielded container when not in use; keep distance and minimise time; wash hands; record keeping.
Allow: AW for all terms. Ignore: references to 'radiation sickness' without explanation. NOT: 'lead stops all radiation'; claims that the GM tube can distinguish energies.
题目 8 · 結構題 with short parts and extended response
15 分
A student determines the Young modulus \(E\) of a long metal wire. The wire hangs vertically from a fixed support and masses are added to a hanger at its lower end. The unstretched length of the wire, measured with a metre rule, is \(L = 2.500 \pm 0.005\) m.
The diameter of the wire is measured with a micrometer screw gauge at five different positions along the wire. The readings are:
\(0.38\) mm, \(0.37\) mm, \(0.39\) mm, \(0.38\) mm, \(0.38\) mm
(a) Determine the mean diameter \(d\) of the wire and the absolute uncertainty in \(d\). Use half of the range of the readings as the absolute uncertainty. [2]
(b) (i) Calculate the cross-sectional area \(A\) of the wire in \(\text{m}^2\). [1]
(ii) Calculate the percentage uncertainty in \(A\). [2]
(c) The student plots a graph of the force \(F\) applied to the wire (vertical axis) against the extension \(x\) of the wire. The line of best fit has gradient \(9.1 \times 10^{3}\) N m\(^{-1}\). The worst acceptable straight line has gradient \(8.7 \times 10^{3}\) N m\(^{-1}\).
(i) Show that the Young modulus of the wire is approximately \(2.0 \times 10^{11}\) Pa. [2]
(ii) Calculate the percentage uncertainty in \(E\). Use your answer to (b)(ii). [2]
(d)* The student's result has a large percentage uncertainty. Evaluate the contributions made by the measurements of \(L\), \(d\) and the gradient of the graph to this uncertainty. Describe the changes to the apparatus or procedure that would reduce the percentage uncertainty in \(E\) and ensure that the wire behaves elastically throughout. [6]
查看答案详解收起答案详解
解题
(a) Mean = (0.38 + 0.37 + 0.39 + 0.38 + 0.38)/5 = 0.38 mm. Range = 0.39 − 0.37 = 0.02 mm, so uncertainty = 0.01 mm. So d = 0.38 ± 0.01 mm.
(c)(ii) % uncertainty in gradient = (9.1 − 8.7)/9.1 × 100 = 4.4%. % uncertainty in L = 0.005/2.500 × 100 = 0.2%. Total = 4.4 + 0.2 + 5.3 = 9.9% (≈ 10%), i.e. E = (2.0 ± 0.2) × 10^11 Pa.
(d) The diameter contributes the most (5.3%) because A depends on d², so its percentage uncertainty is doubled and the micrometer reading is only about 0.38 mm, so the 0.01 mm uncertainty is relatively large. The gradient contributes 4.4%, which comes from the scatter of the points about the line. The length contributes only 0.2% and is negligible. Improvements: take more diameter readings at different positions and in perpendicular orientations and use the ratchet; check and correct for zero error; use a longer wire or a more sensitive method (travelling microscope, vernier scale or reference wire) to measure larger extensions with smaller percentage uncertainty; take more readings over a wider range of load and repeat; use a graph with a line of best fit; do not exceed the elastic limit, check by unloading and confirming that the extension returns to zero; apply an initial small load to remove kinks.
评分标准
(a) B1: mean d = 0.38 mm. B1: uncertainty = 0.01 mm (half of range 0.02 mm). Allow 0.38 ± 0.01 mm as one statement for both marks. [2]
(b)(i) B1: A = 1.1 × 10^-7 m^2 (allow 1.13 × 10^-7). Allow ECF for d from (a). NOT if mm^2 used without conversion. [1]
(b)(ii) M1: % uncertainty in d = 0.01/0.38 × 100 = 2.6% (allow 2.6–2.7%). A1: doubled for d², so 5.3% (allow 5.2–5.4%; ECF from (a)). Using the 'absolute uncertainty in A' route is acceptable if correct. [2]
(c)(i) M1: E = (F/A)/(x/L) rewritten as gradient × L/A, or substitution of 9.1 × 10^3, 2.500 and the area. A1: E = 2.0 × 10^11 Pa (must show an unrounded value, e.g. 2.01 × 10^11, or at least 3 s.f., to be credited). Ignore unit Pa = N m^-2. [2]
(c)(ii) M1: percentage uncertainties of gradient (4.4%, allow 4.3–4.4%) and L (0.2%) found and added to the % uncertainty in A. A1: 9.9% (allow 10%); ECF from (b)(ii). Allow absolute uncertainty ±0.2 × 10^11 Pa as an alternative to the percentage if clearly the result of the correct addition. NOT combining by subtraction. [2]
(d)* Level of response, assessed holistically. [6]
Indicative scientific points: - % uncertainty in d (2.6%) is doubled to 5.3% in A as A ∝ d², so d is the largest contributor. - Gradient uncertainty (4.4%) is the second largest; due to scatter / limited range of readings. - Uncertainty in L (0.2%) is negligible. - Diameter: more readings at different positions / orientations (perpendicular directions); use the ratchet; check zero error; average the readings. Allow a thicker wire, but only if the extension is still measurable. - Extension: use a longer wire, larger loads (within the elastic limit) or a travelling microscope / vernier scale to measure the extension with a smaller percentage uncertainty. - Gradient: more data points over a larger range, repeat readings for each load, use a best-fit line. - Elastic behaviour: do not exceed the elastic limit; unload and check that the extension returns to zero; the graph should be linear through the origin; use an initial load to remove kinks.
5–6 marks: A sound evaluation that ranks all three contributions with quantitative support (d largest because squared, then gradient, L negligible) and gives at least three relevant, justified improvements, including one linked to the elastic limit. The reasoning is logically structured and clearly links each improvement to a reduction in uncertainty. 3–4 marks: Identifies the main contributions (at least d and gradient) with some quantitative or reasoned support, and gives at least two relevant improvements. Some reasoning may be incomplete, or the elastic behaviour may be omitted. 1–2 marks: Makes limited relevant statements, such as one contribution or one or two improvements, with little or no justification or linking. 0 marks: No creditworthy response.
Allow ECF from earlier values in the evaluation of contributions. Ignore references to human error or to 'using a more accurate micrometer' without justification.
部分 H556/03 All questions
Answer every question and show working where appropriate. Questions use lettered parts and Roman-numeral subdivisions where needed. Two six-mark responses assess the quality of extended reasoning; these marks are included within the question totals.
6 题目 · 70 分
题目 1 · structured
7 分
A student determines the specific heat capacity \(c\) of a solid metal block using an electrical heater placed in a hole in the block. The block is wrapped in a layer of insulating foam. The student records the following measurements.
| quantity | value | |---|---| | mass of block, \(m\) | \(0.500 \pm 0.002\) kg | | potential difference across heater, \(V\) | \(12.0 \pm 0.1\) V | | current in heater, \(I\) | \(3.00 \pm 0.05\) A | | heating time, \(t\) | \(300 \pm 1\) s | | temperature rise of block, \(\Delta\theta\) | \(24.0 \pm 1.0\) K |
(a) (i) Calculate the specific heat capacity \(c\) of the metal, in \(\mathrm{J\,kg^{-1}\,K^{-1}}\). [2]
(ii) Determine the absolute uncertainty in \(c\). Give your answer to an appropriate number of significant figures. [3]
(b) Suggest, with a reason, one change to the procedure that would reduce the percentage uncertainty in \(c\) by the greatest amount. [1]
(c) State and explain the effect, if any, of thermal energy transferred to the surroundings on the value of \(c\) calculated in (a)(i). [1]
查看答案详解收起答案详解
解题
(a)(i) Energy supplied \(E = VIt = 12.0 \times 3.00 \times 300 = 1.08\times10^{4}\) J. \(c = E/(m\Delta\theta) = 10800/(0.500\times 24.0) = 900\ \mathrm{J\,kg^{-1}\,K^{-1}}\).
(b) The temperature rise has by far the largest percentage uncertainty (4.2%). Heat for longer (or use a thermometer with finer resolution) so that \(\Delta\theta\) is larger and the 1.0 K uncertainty is a smaller fraction of it.
(c) Some of the energy supplied is lost to the surroundings, so the energy gained by the block is less than \(VIt\). The temperature rise is smaller than it should be, so the calculated \(c\) is too large.
评分标准
(a)(i) M1: \(E = VIt\) (= 10 800 J) used in \(c = E/(m\Delta\theta)\). A1: 900 \(\mathrm{J\,kg^{-1}\,K^{-1}}\). Allow \(9.0\times10^{2}\). Ignore number of significant figures of 2 or more.
(a)(ii) M1: calculates the fractional or percentage uncertainty in each of the five quantities (at least four correct). M1: adds the percentage uncertainties (7.4%; allow 7.3 to 7.5%). A1: absolute uncertainty = 67 (allow 66 to 68), quoted to 1 or 2 s.f. (70 or 67). NOT 3 or more s.f. NOT adding absolute uncertainties directly. ECF allowed for the final A1 from the candidate's total percentage uncertainty.
(b) B1: heat for longer / produce a larger temperature rise / use a thermometer with smaller resolution AND reason that the percentage uncertainty in \(\Delta\theta\) is the largest or would be reduced. AW. Ignore improvements to \(m\), \(V\), \(I\) or \(t\) only. Both change and reason are required.
(c) B1: calculated \(c\) is too large (greater than true value) because the energy supplied is greater than that gained by the block / temperature rise is smaller than expected. ORA. NOT 'inaccurate' without direction.
题目 2 · 結構題 with short parts and extended response
9 分
A narrow parallel beam of monoenergetic X-rays is directed at a plate of aluminium of thickness \(4.0\,\text{mm}\). The intensity of the transmitted beam is \(0.35\) of the incident intensity \(I_0\).
(a) Calculate the linear attenuation coefficient \(\mu\) of aluminium for these X-rays. Give your answer in \(\text{mm}^{-1}\).
(b)* A radiographer takes an X-ray image of a patient's forearm to look for a bone fracture. A thin aluminium sheet is placed in the beam between the X-ray tube and the patient. In a separate examination of the digestive system, the patient swallows a barium meal before being imaged.
In your answer you should: - explain why the bone appears clearly on the image of the forearm - explain the purpose of the aluminium sheet placed before the patient - explain why the barium meal is needed to produce a clear image of the digestive system.
[6]
查看答案详解收起答案详解
解题
(a) Use \(I = I_0 e^{-\mu x}\). Then \(0.35 = e^{-\mu \times 4.0}\), so \(\mu = \ln(1/0.35)/4.0 = 1.050/4.0 = 0.262\,\text{mm}^{-1}\) (0.26 mm^-1 to 2 s.f.).
(b) Bone has a much larger attenuation coefficient than soft tissue because it is denser and contains atoms of higher proton number (calcium), so photoelectric absorption is greater. Intensity transmitted through bone is therefore much lower than through the surrounding tissue, giving contrast between bone and soft tissue on the detector. The aluminium sheet preferentially absorbs low-energy X-ray photons, which have a larger attenuation coefficient and would be absorbed in the patient's tissue, increasing the dose without reaching the detector. The beam passing into the patient is then of higher mean energy, reducing patient dose and improving image sharpness. Soft tissues in the digestive system have almost the same attenuation coefficient as neighbouring tissue so produce very little contrast. Barium (high proton number) has a very high attenuation coefficient, absorbs far more X-rays than the surrounding tissue, and so the barium-filled organ shows clearly against the background; the barium is non-toxic in an insoluble form and is not absorbed into the body.
评分标准
(a) 3 marks M1: use of \(I = I_0 e^{-\mu x}\) with \(I/I_0 = 0.35\) and \(x = 4.0\) mm (or \(\mu x = \ln(1/0.35)\)). [1] M1: correct rearrangement/use of natural logarithm, \(\ln(1/0.35)\) or \(-\ln 0.35 = 1.05\). [1] A1: \(\mu = 0.26\,\text{mm}^{-1}\) (0.262 mm^-1). Allow 0.25 to 0.27 only if working shown. NOT a negative value. Allow 262 m^-1 (or 260 m^-1) if the unit is stated. NOT 0.026 mm^-1. [1]
(b)* 6 marks. Level of response marking, assessed holistically.
Indicative scientific points: - Bone has a larger attenuation (absorption) coefficient than soft tissue / bone absorbs more X-rays (higher density and/or higher proton number, calcium). - Lower intensity transmitted through bone than through soft tissue, giving contrast (bone appears lighter/white on the film or detector: AW). - Aluminium sheet removes/absorbs low-energy (soft) X-ray photons. - Low-energy photons would be absorbed by the patient's body and not reach the detector, so they increase dose without improving the image. - Beam is hardened / mean photon energy raised, so dose is reduced and image quality is maintained. - Soft tissue of the digestive system has similar attenuation to neighbouring tissue so there is little contrast. - Barium has a high proton number / high attenuation coefficient, so it absorbs strongly and outlines the organ (barium meal is a contrast medium). - Barium is chemically inert/insoluble so safe to swallow (allow, not essential).
Band 3 (5-6 marks): All three requirements addressed with correct, clearly linked physics; explanations connect attenuation coefficient or absorption to the observed contrast or dose reduction. Reasoning is coherent and logically structured with few or no omissions. Band 2 (3-4 marks): At least two requirements addressed with some correct physics, or all three addressed but with limited explanation (for example statements without a link to attenuation or absorption). Reasoning is mostly logical but may have gaps. Band 1 (1-2 marks): One requirement addressed, or isolated correct statements with little linkage or explanation. Band 0 (0 marks): No response or no creditworthy physics.
Guidance: Allow 'denser' and 'higher atomic number' for bone. Ignore references to X-ray wavelength being 'absorbed by' ionisation unless contradicting. NOT 'bone reflects X-rays'. NOT 'aluminium sheet stops all X-rays' or 'blocks the harmful rays' without reference to low-energy photons. NOT 'barium emits X-rays'.
题目 3 · 結構題 with short parts and extended response
12 分
A student determines the specific heat capacity \(c\) of an aluminium block using an electric heater. The heater is placed in a hole drilled in the block and a thermometer is placed in a second hole. The block is not insulated.
The student records the following data, each with its absolute uncertainty.
| quantity | value | absolute uncertainty | |---|---|---| | mass of block, \(m\) | 1.00 kg | \(\pm 0.01\) kg | | potential difference across heater, \(V\) | 12.0 V | \(\pm 0.1\) V | | current in heater, \(I\) | 3.50 A | \(\pm 0.05\) A | | heating time, \(t\) | 300 s | \(\pm 1\) s | | temperature rise, \(\Delta\theta\) | 14.0 K | \(\pm 1.0\) K |
(a) Assume that all of the electrical energy supplied is transferred to the block. Calculate the specific heat capacity of aluminium given by these data. [3]
(b) Determine the percentage uncertainty in the value of \(c\) calculated in (a) and hence the absolute uncertainty in \(c\). Give your answer for \(c\) in the form \(c \pm \Delta c\). [3]
(c)* The student wishes to obtain a more accurate and more precise value of \(c\). Your answer should: - identify the measurement that contributes most to the uncertainty in \(c\) and describe a change to the procedure that reduces its effect - describe how a graph of temperature against time could be used to find \(c\), stating what is calculated from the graph - explain whether the value of \(c\) calculated in (a) is likely to be too large or too small, and describe how the apparatus could be modified to reduce this systematic error. [6]
查看答案详解收起答案详解
解题
(a) \(P = VI = 12.0 \times 3.50 = 42.0\) W. \(E = Pt = 42.0 \times 300 = 1.26\times10^{4}\) J. \(c = E/(m\Delta\theta) = 1.26\times10^{4}/(1.00\times14.0) = 900\ \mathrm{J\,kg^{-1}\,K^{-1}}\).
(c) The temperature rise has the largest percentage uncertainty (7%). Heating for longer (for example 600 s) doubles \(\Delta\theta\) so its percentage uncertainty halves; a thermometer with finer resolution would also help. Plot \(\theta\) against \(t\) at regular intervals and draw a line of best fit. The gradient is \(\Delta\theta/\Delta t\) and \(c = P/(m \times \text{gradient})\), which averages out random errors and allows anomalies to be identified. Because the block is not insulated, some energy is transferred to the surroundings, so the energy absorbed by the block is less than \(VIt\). The temperature rise is therefore smaller than it should be and the calculated \(c\) is too large. Lagging the block with insulating material (and a lid), and using a little oil in the thermometer hole for good thermal contact, reduces the error.
评分标准
(a) M1: \(P = VI = 42.0\) W (or \(E = VIt\)). M1: \(E = 1.26\times10^{4}\) J and use of \(E = mc\Delta\theta\) rearranged for \(c\). A1: \(c = 900\ \mathrm{J\,kg^{-1}\,K^{-1}}\). Allow 1 or 2 s.f. (9 × 10^2). Unit required for A1; NOT missing or wrong unit. [3]
(b) B1: percentage uncertainty in \(\Delta\theta\) = 7.1% (7.14%) AND at least three other correct percentage uncertainties seen (0.83%, 1.43%, 1.0%, 0.33%). M1: percentages added (not subtracted, not combined in quadrature) to give about 10.7% (11%). Allow ECF from B1. A1: absolute uncertainty about 96, quoted as \(c = (900 \pm 100)\) with unit; allow \(900 \pm 96\). Ignore \(\pm 90\) to \(\pm 100\) from rounding. ECF from M1. [3]
(c)* Level of response, holistic.
Band 3 (5–6 marks): All three strands addressed with correct, supported physics. The temperature rise is identified as the dominant uncertainty with a change that clearly reduces its percentage effect; the graph method is described with the gradient and a correct expression for \(c\); the direction of the systematic error is correct and explained in terms of energy losses, with a suitable modification. The reasoning is logical and connected.
Band 2 (3–4 marks): Two strands addressed well, or all three addressed with some omissions or lack of explanation (for example no link between losses and the direction of error, or the gradient not related to \(c\)).
Band 1 (1–2 marks): Some relevant points made, usually from one strand only, with limited explanation or reasoning.
Band 0 (0 marks): No creditworthy response.
Indicative scientific points: - \(\Delta\theta\) has the largest percentage uncertainty (about 7%) - heat for longer / increase \(\Delta\theta\) so percentage uncertainty falls; or use thermometer of better resolution (e.g. 0.1 K) - take temperature readings at regular time intervals and plot \(\theta\) against \(t\) - gradient = \(\Delta\theta/\Delta t\); \(c = P/(m \times \text{gradient})\) (AW, e.g. \(c = VI/(m \times\) gradient)) - best-fit line reduces random error; anomalies identifiable - energy is lost to the surroundings, so not all electrical energy raises the temperature of the block - measured \(\Delta\theta\) too small, so \(c\) too large (ORA); systematic error - lag the block / use insulation / lid; oil in thermometer hole for thermal contact Allow: repeating the experiment and averaging as an additional point only if linked to reducing random error. Ignore: reference to human reaction time unless linked to \(t\). NOT: 'c is too small' without a consistent explanation; NOT: 'use a more accurate ammeter' as the main source of uncertainty. [6]
Total [12]
题目 4 · 結構題 with short parts and extended response
13 分
1 A student investigates how a narrow beam of X-rays is attenuated by aluminium. Identical aluminium sheets are stacked between the source and a detector. The detector reading \(I\) is recorded for different total thicknesses \(x\) of aluminium.
The intensity is expected to obey \(I = I_0 e^{-\mu x}\), where \(\mu\) is the linear attenuation coefficient.
(a) A graph of \(\ln I\) against \(x\) is plotted. Show that this graph should be a straight line and state what the gradient represents. [2]
(b) Use the data for \(x = 0\) and \(x = 8.0\) mm to determine \(\mu\), in \(\text{mm}^{-1}\). [3]
(c) Calculate the thickness of aluminium that reduces the intensity to half of its incident value. [2]
(d)* A radiographer needs a clear image of a hollow organ lying next to soft tissue. The X-ray tube output is passed through a thin aluminium filter and the patient swallows a barium-containing liquid before the exposure.
Explain how the image is formed and why the filter and the barium liquid each improve the diagnostic quality of the image. [6]
查看答案详解收起答案详解
解题
(a) Take natural logs of \(I = I_0 e^{-\mu x}\): \(\ln I = \ln I_0 - \mu x\). This has the form \(y = c + mx\), so the graph is a straight line with intercept \(\ln I_0\) and gradient \(-\mu\) (the magnitude of the gradient is the attenuation coefficient).
(c) \(x_{1/2} = \dfrac{\ln 2}{\mu} = \dfrac{0.693}{0.150} = 4.6\) mm.
(d) Indicative content: X-rays are attenuated differently by different tissues, so the transmitted intensity varies across the detector and forms a shadow image. Attenuation depends on the density and proton number of the material (\(I = I_0 e^{-\mu x}\)). Soft tissues have similar \(\mu\), so contrast between a hollow organ and its surroundings is poor. Barium has a large proton number, so it absorbs strongly; it fills the organ and gives high contrast. Low-energy photons are absorbed in the body and add to patient dose without reaching the detector. The aluminium filter preferentially absorbs these low-energy photons, so the beam is harder, the patient dose falls, and the image is less blurred and clearer.
评分标准
(a) B1: takes logarithms of both sides / \(\ln I = \ln I_0 - \mu x\). B1: compares with \(y = mx + c\) and states gradient \(= -\mu\) (allow magnitude of gradient \(= \mu\)). Total 2.
(b) M1: \(\ln(I_0/I)\) or \(\ln(100/30)\) (or \(\ln 30 - \ln 100\)) used with \(x = 8.0\). A1: \(1.204/8.0\) evaluated. A1: \(0.15\ \text{mm}^{-1}\) (allow 0.150; accept 0.15 to 2 or 3 s.f.). A bare correct answer scores 3. Total 3. Ignore sign if magnitude is correct; NOT a negative value unless stated as the gradient.
(c) C1/M1: \(x_{1/2} = \ln 2/\mu\) or \(0.5 = e^{-\mu x}\). A1: 4.6 mm (4.62 using 0.150). ECF from (b). Total 2.
(d) Level of response, 6 marks. Indicative scientific points: (1) differential attenuation by tissues / bone absorbs more, so shadow image; (2) attenuation depends on density and proton number; (3) soft tissues have similar attenuation so poor contrast; (4) barium has high proton number so absorbs strongly (contrast medium) and outlines organ; (5) low-energy X-rays are absorbed by the body without contributing to the image; (6) filter removes low-energy photons, reducing patient dose; (7) filter gives a harder, more intense/narrower-energy beam so clearer image / sharper. Band 3 (5-6 marks): explains image formation AND the role of both barium and filter with correct, linked physics (attenuation, proton number, photon energy, dose). Reasoning is logical, complete and well supported. Band 2 (3-4 marks): addresses image formation and at least one of the two measures with some correct explanation, or all three at a descriptive level with limited linking. Band 1 (1-2 marks): makes isolated relevant statements, e.g. barium absorbs X-rays or the filter removes some X-rays, with little explanation. Band 0 (0 marks): no creditworthy response. Allow AW throughout. Ignore references to ionising effects of X-rays unrelated to dose. NOT 'barium is radioactive'.
题目 5 · structured
14 分
A sealed source contains a radioisotope that emits only gamma radiation. At the start of a laboratory investigation the activity of the source is \(4.8 \times 10^{5}\) Bq. The half-life of the radioisotope is 6.0 hours.
(a) (i) Define the decay constant of a radioactive nuclide. [1]
(ii) Show that the decay constant of the radioisotope is approximately \(3.2 \times 10^{-5}\ \text{s}^{-1}\). [2]
(iii) Calculate the activity of the source 20 hours after the start of the investigation. [2]
(b) A narrow beam of the gamma radiation is directed at a detector. The background count rate has already been subtracted from every reading. With no absorber, the corrected count rate is \(840\ \text{s}^{-1}\). When a lead sheet of thickness 15 mm is placed in the beam, the corrected count rate falls to \(105\ \text{s}^{-1}\).
The intensity of the radiation transmitted through a thickness \(x\) of absorber is given by \(I = I_0 e^{-\mu x}\).
Calculate the linear attenuation coefficient \(\mu\) of lead for this radiation. Give your answer in \(\text{mm}^{-1}\). [3]
(c)* A student wishes to determine \(\mu\) for lead using a set of lead sheets of different thicknesses, a source of gamma radiation and a Geiger-Muller tube connected to a counter.
Describe how the investigation should be carried out and how the results should be analysed to obtain \(\mu\). Your answer should include: - the measurements to be made and how the accuracy of the data can be improved - how the data are processed and presented graphically - a safety precaution. [6]
查看答案详解收起答案详解
解题
(a)(i) The decay constant is the probability of decay of a nucleus per unit time (equivalently, the constant of proportionality between activity and the number of undecayed nuclei, \(A = \lambda N\)).
(a)(ii) \(t_{1/2} = 6.0 \times 3600 = 2.16\times10^{4}\) s. \(\lambda = \ln 2 / t_{1/2} = 0.693 / 2.16\times10^{4} = 3.21\times10^{-5}\ \text{s}^{-1}\), which is approximately \(3.2\times10^{-5}\ \text{s}^{-1}\).
(c) Indicative content: place the source and GM tube at a fixed separation with the lead sheet between them, source-detector distance and alignment unchanged throughout. Measure the thickness of each sheet with a micrometer (or vernier calipers), at several places, and take a mean. Measure the background count with the source removed or shielded, over a long time, and subtract it from every reading. For each thickness count for a long time (e.g. 60 s or more) so that the random uncertainty (about the square root of the count) is a small percentage, repeat and take a mean, and convert to a count rate. Use a range of thicknesses (including stacked sheets) so that the corrected rate stays clearly above the background. The half-life is much longer than the time of the experiment, so the source activity is effectively constant (or readings can be corrected for decay). Processing: \(C = C_0 e^{-\mu x}\) so \(\ln C = \ln C_0 - \mu x\). Plot \(\ln C\) against \(x\) with labelled axes and units; draw a best-fit straight line; gradient = \(-\mu\); the intercept gives \(\ln C_0\). Safety: handle the source with tongs, keep it as far from the body as practicable, point it away from people, keep exposure time short and return it to its lead-lined storage box immediately after use.
评分标准
(a)(i) B1: probability (chance) of decay of a nucleus per unit time (AW; allow constant of proportionality in \(A = \lambda N\) with symbols defined). NOT 'rate of decay' alone. [1]
(a)(ii) C1: converts hours to seconds (\(6.0\times3600 = 2.16\times10^{4}\) s). A1: \(\lambda = \ln2/t_{1/2} = 3.2(1)\times10^{-5}\ \text{s}^{-1}\); the answer must be shown to at least 3 s.f. or the substitution clearly shown. Allow working in hours with a correct conversion at the end. [2]
(a)(iii) M1: use of \(A = A_0 e^{-\lambda t}\) with correct t (\(7.2\times10^{4}\) s), or \(A = A_0 (1/2)^{t/t_{1/2}}\) with \(t/t_{1/2} = 3.33\). A1: \(4.8\times10^{4}\) Bq. Allow \(4.7\times10^{4}\) to \(4.8\times10^{4}\) Bq. ECF from (a)(ii) for the value of \(\lambda\) only. [2]
(b) C1/M1: \(105/840 = e^{-15\mu}\) (or 840/105 = 8 used correctly). M1: takes natural logs correctly, \(\ln 8 = 2.08\), \(15\mu = 2.08\). A1: \(\mu = 0.139\ \text{mm}^{-1}\). Allow 0.14. Allow 139 m^-1 or 13.9 cm^-1 only if the unit is correct; unit given as required is mm^-1. Allow a half-value-thickness route: three half-values, so \(x_{1/2} = 5.0\) mm and \(\mu = \ln2/5.0 = 0.139\). Award full marks for a correct answer. [3]
(c)* Level 3 (5-6 marks): a clear, logical and complete description covering all three strands: measurements with at least two improvements to accuracy or precision (e.g. background subtraction, repeats or long counting times, fixed geometry, measuring thickness with a suitable instrument); correct linearisation and graph (ln C against x, gradient = -mu); and a valid safety precaution. Reasoning is well structured and the links between the method and the analysis are clear. Level 2 (3-4 marks): a description that covers two strands well or all three with some gaps; a method that would produce usable data but lacks some detail (e.g. the graph is mentioned without the log, or the background is mentioned without the corrected rate). Level 1 (1-2 marks): some relevant points with limited organisation, for example measuring count rate for different thicknesses, but with little about the improvement of accuracy or the analysis. 0 marks: no creditworthy response. Indicative points (not a compulsory script): fixed source-detector distance and alignment; measure the background rate with the source removed and subtract it; count for a long time or repeat and average (random nature of decay, small percentage uncertainty); measure sheet thickness with a micrometer or calipers; use a range of thicknesses; the source activity is effectively constant over the time because the half-life is long (or correct for decay); plot ln(corrected count rate) against thickness; straight line with a negative gradient; \(\mu = -\) gradient; the intercept is \(\ln C_0\); safety: tongs, distance, short exposure, source not pointed at people, store in a lead-lined box. Allow plotting ln of the ratio \(C/C_0\). Ignore wearing gloves or goggles as the sole precaution. Allow a graph of C against x with an exponential fit, or a half-value-thickness method, only if \(\mu = \ln 2/x_{1/2}\) is used, but this may not score above Level 2 unless the averaging of several half-value thicknesses is described. [6]
Total: 14 marks.
题目 6 · 結構題 with short parts and extended response
15 分
A technician investigates how a narrow beam of X-rays is attenuated by aluminium sheet. A detector measures the intensity of the beam. Without any aluminium in the beam the intensity is \(I_0 = 640\ \mathrm{W\,m^{-2}}\). When a sheet of aluminium of thickness \(x = 8.00\ \mathrm{mm}\) is placed in the beam, the intensity falls to \(I = 160\ \mathrm{W\,m^{-2}}\).
The uncertainty in \(I_0\) is \(\pm 16\ \mathrm{W\,m^{-2}}\), the uncertainty in \(I\) is \(\pm 8\ \mathrm{W\,m^{-2}}\) and the uncertainty in \(x\) is \(\pm 0.02\ \mathrm{mm}\).
The intensity of a narrow beam after passing through a thickness \(x\) of a material is given by \(I = I_0 e^{-\mu x}\).
(a) (i) State what is meant by the linear attenuation coefficient \(\mu\). [1]
(ii) Calculate \(\mu\) for aluminium, in \(\mathrm{mm^{-1}}\). [2]
(iii) Determine the thickness of aluminium needed to reduce the intensity of the beam to half of its initial value. [2]
(b) Determine the percentage uncertainty in your value of \(\mu\) from (a)(ii) and hence write \(\mu\) with its absolute uncertainty. [3]
(c)* Describe and explain how an X-ray image of a broken bone in a leg is formed, and how the quality of the image and the safety of the patient can each be improved. You should refer to the properties of the X-ray beam, the tissues involved and the way the detector is used. [6]
(d) The X-ray tube may be treated as a point source in a vacuum. State why the intensity of the beam still decreases with distance from the tube, even though no material absorbs it. [1]
查看答案详解收起答案详解
解题
(a)(i) \(\mu\) is the constant in \(I=I_0e^{-\mu x}\); it equals the fractional decrease in intensity per unit thickness of the material for a narrow beam.
(b) Percentage uncertainties: \(I_0\): 16/640 = 2.5%; \(I\): 8/160 = 5.0%. The ratio \(I_0/I\) has uncertainty 7.5%, so the absolute uncertainty in \(\ln 4\) is \(\approx 0.075\) (checking extremes: \(\ln(656/152)=1.462\), \(\ln(624/168)=1.312\)). This is \(0.075/1.386 = 5.4\%\). Uncertainty in \(x\): 0.02/8.00 = 0.25%. Total \(\approx 5.7\% \approx 6\%\). Absolute uncertainty \(= 0.057 \times 0.173 = 0.010\ \mathrm{mm^{-1}}\). So \(\mu = 0.173 \pm 0.010\ \mathrm{mm^{-1}}\).
(c) Indicative content: X-rays are produced by a tube and directed at the leg, with the detector (film or digital sensor) behind it. Absorption depends on \(\mu\), which is larger for bone (higher density and proton number, calcium) than for soft tissue, so bone transmits less and appears lighter/shows a fracture as a gap in the shadow. A narrow, collimated beam and a small source/focus give sharp images; an anti-scatter grid removes scattered X-rays that blur the image; placing the detector close to the leg reduces blurring. Contrast between tissues is improved by choosing a suitable X-ray photon energy; a contrast medium can be used for soft tissue. A metal (aluminium) filter removes low-energy X-rays, which would be absorbed in the skin without contributing to the image, reducing dose. A short exposure time, sensitive digital detector or intensifying screen lowers the dose. Shielding of other body areas and limiting the number of exposures also reduces risk.
(d) Intensity \(\propto 1/r^2\) (inverse square law): the same power is spread over a larger area as the beam diverges.
评分标准
(a)(i) B1: fraction (proportion/percentage) of intensity absorbed/removed per unit thickness (AW); or constant in I = I0 e^(-mu x) with the symbols defined. Allow 'depends on material and photon energy'. NOT just 'how much is absorbed'. [1]
(a)(ii) M1: ln(I0/I) = mu x or ln(160/640) = -mu x (ln 4 = 1.386 seen). A1: mu = 0.173 mm^-1 (allow 0.17; allow 173 m^-1 with unit). Allow a 1-mark answer if the unit is missing or wrong with correct value. [2]
(a)(iii) C1: x = ln 2 / mu (allow ln 2 = mu x, or I/I0 = 0.5 used). A1: 4.0 mm (ECF from (a)(ii); allow 4 mm; also allow answer of exactly 4.0 mm from 2 x 8/4 reasoning, i.e. 640 -> 320 -> 160 two half-thicknesses). [2]
(b) M1: percentage uncertainties of I0 (2.5%) and I (5.0%) added (7.5%) or extreme values of ln (1.312 and 1.462) used. A1: percentage uncertainty in ln(I0/I) = 5.4% (allow 5% to 6%). A1: total percentage uncertainty in mu approx 5.7% (allow 6%, allow 5.5% to 6%) and mu = 0.173 +/- 0.010 mm^-1 (allow +/-0.01). Do not penalise 0.17 +/- 0.01. Allow ECF from (a)(ii) for the value of mu only. Do NOT credit adding the percentage uncertainty of ln 4 as 7.5% directly (max 1 mark). [3]
(c)* Level of response, 6 marks. Indicative scientific points: (1) X-ray photons produced by tube, passed through leg to detector; (2) bone has greater mu / absorbs more than soft tissue (higher density / proton number); (3) differential absorption produces contrast / shadow image; (4) collimated narrow beam or small source gives sharper image; (5) anti-scatter grid or detector close to leg to reduce blurring; (6) suitable photon energy or contrast medium to improve contrast; (7) aluminium filter removes low-energy X-rays so reducing patient dose; (8) short exposure, sensitive detector or intensifying screen reduces dose; (9) shielding or limiting number of exposures. 5-6 marks: Describes how the image is formed AND gives explained methods for improving both image quality and patient safety, linking each to the physics (e.g. mu, absorption, scattering, filtering). Reasoning is logical, complete and well structured, with at least two points supported for each of quality and safety. 3-4 marks: Describes image formation with some explanation, and gives measures for improving quality and/or safety. Some links are made to the physics but the explanation is incomplete, or one strand (quality or safety) is missing or only stated. 1-2 marks: Makes isolated relevant statements (e.g. bone absorbs more X-rays; a filter is used) with little or no explanation or logical structure. 0 marks: No response or no creditworthy response. [6]
(d) B1: inverse square law / intensity proportional to 1/r^2 / energy (power) spread over increasing area as the beam spreads out (AW). Ignore 'attenuation'. [1]
Total: 15 marks.
想知道自己有几分把握?
thinka 是 DSE 学生在用的 AI 练习应用,提供无限量练习题、即时自动批改和详细解题步骤。超过 100,000 名学生用它确认自己是真的会,而不只是「以为会」。